Analyte and label binding assay read by flow cytometry.
نویسندگان
چکیده
A new immunometric two-site sandwich assay is introduced, in which a label-scavenging binding partner is added to the sample in addition to the analyte-binding partner. The scavenger binding partner binds excess label antibody, giving a signal proportional to the amount of excess label antibody in the sample solution. A set of two calibration curves is obtained from the two binding partners simultaneously, and a combination of the two signals gives an unambiguous determination of the analyte concentration, even for high analyte concentrations where the hook effect may occur. Two-particle immunofluorometric assays developed for placental alkaline phosphatase and human chorionic gonadotropin on the basis of this principle and yielding signals measured by flow cytometry gave rapid results (2 h) and had working ranges in excess of 5 and 6 orders of magnitude for the respective analytes.
منابع مشابه
Overview of Luminex Assay Performance
Luminex Assay Design and Methods. Luminex assays use antibody-conjugated bead sets to detect analytes in a multiplexed sandwich immunoassay format. Each bead in the set is identified by a unique content of two addressing dyes, with a third dye used to read out binding of the analyte via a biotin-conjugated antibody and streptavidin-conjugated second step detector. Data is acquired on a dedicate...
متن کاملKinetic Characterization of Antibody/Antigen Interactions
A leading application of biomolecular interaction analysis technology is the characterization of antibodyantigen interactions. By measuring the association and dissociation rates of the interaction, antibodies with desired binding characteristics can be identified. A rapid association rate and a slow dissociation rate may be indicative of therapeutic efficacy. Affinity maturation programs exist...
متن کاملDirect quantification of analyte concentration by resonant acoustic profiling.
BACKGROUND Acoustic sensors that exploit resonating quartz crystals directly detect the binding of an analyte to a receptor. Applications include detection of bacteria, viruses, and oligonucleotides and measurement of myoglobin, interleukin 1beta (IL-1beta), and enzyme cofactors. METHODS Resonant Acoustic Profiling was combined with a microfluidic lateral flow device incorporating an internal...
متن کاملICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders part 4 - assay validation and quality assurance.
Over the past six years, a diverse group of stakeholders have put forth recommendations regarding the analytical validation of flow cytometric methods and described in detail the differences between cell-based and traditional soluble analyte assay validations. This manuscript is based on these general recommendations as well as the published experience of experts in the area of PNH testing. The...
متن کاملFlow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates
Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 42 10 شماره
صفحات -
تاریخ انتشار 1996