Building and Environment
نویسندگان
چکیده
Precise prediction of particulate movement is needed to provide a better understanding of how airborne disease organisms move within ventilated facilities. Bacteria often adhere to larger airborne particulates, which will modify their movement behavior in ventilated rooms and may provide an environment to allow them to remain virulent longer. An empty chamber (206 H x 203 W x 386 cm L) with a circular air inlet and outlet on opposite ends was ventilated with air that had a known particulate density. The inlet and outlet openings were sized to maintain inlet and exit velocities at around 5.1 m/s at 5 different air exchange rates (around 2, 4, 5, 9, and 14 air changes per hour e ACH). Particulate concentrations were measured at the air outlet and at 12 locations within the chamber. In this study, the particulate concentration in the inlet air remained constant, so the amount of particulates injected into the chamber increased as the ACH increased. The measured particulate levels at the outlet also increased essentially linearly with an increase in ACH. However, the particulate concentrations in the occupied zone of the chamber did not increase linearly with an increase in actual ACH. Rather, it increased essentially linearly at the lower ACH levels (from around 2 to 5 ACH), but then leveled out at the higher ACH values. The advantages of increasing ACH in terms of providing better environments in the occupied zone of rooms may have limits, which warrant further investigation. © 2013 Elsevier Ltd. All rights reserved.
منابع مشابه
Teachers ‘professional development and conceptual change through the knowledge building environment
This study aimed to investigate conceptual change as a fruitful framework in teachers’ professional development through knowledge building environment. In cognitive approaches towards education, the quality of education is seen as a result of teachers’ actions and teachers’ action is seen as a result of their cognition. Thereby the goal of many teachers’ professional development programs is to ...
متن کاملThe relationship between delegated responsibilities to the HSE employees and the performance indicators in the building construction projects in urban areas
Construction projects are one of the most important economic sectors in the world. At the same time, these projects are one of the hazardous industries that cause many accidents resulting from injuries and deaths, occupational diseases, delay in time, environmental problems and other direct and indirect damages. While in many industries, the issue of health, safety and environment is meticulous...
متن کاملAn Investigation of Sick Building Syndrome (SBS) in Workplaces, (Case Study: Engineering Organization Building of Urmia).
Background and objectives: Undoubtfuly, people spend a significant portion of their time in workplaces. Many factors affect the health and well-being of employees. The present study aimed to identify the architectural problems of the environment by examining the symptoms of Sick Building Syndrome and ranking the parameters influenced by five physical factors (thermal comfort, noise, lighting, l...
متن کاملEnvironment as a Pattern for Design. Case study: Shandiz valley in Mashhad - Iran
The aim of this paper is to review the created problems and failure of environmental design patterns in designing process by designers. Not respectfully addressing the context of environment during designing process have resulted in the loss quality of environment, damage to both nature and essence of environment as manifested in the case study area. Methodology of the research was based on the...
متن کاملFrequency of Sick Building Syndrome and Its Related Factors in Nurses at Ali Ibn Abitaleb Hospital in Rafsanjan City 2018: A Cross-Sectional Study
Background and Objectives: Sick building syndrome (SBS) is a building-related illness in which people in the environment do not experience proper physical and mental well-being. Mental and physical changes include headache, nausea, abnormal fatigue, lack of concentration, sensation of an unpleasant odor. Thus, the aim of this study was to investigate the frequency of SBS and its related factors...
متن کاملQuantification of Thermal Energy Performance Improvement for Building Integrated Photovoltaic Double-Skin Façade Using Analytical Method
In this research, an analytical method for quantification of the thermal energy performance improvement for a building integrated photovoltaic double-skin façade has provided. The system has been suggested as a retrofit measure for an existing building in Tehran. The effect of thermal performance has been analyzed through computer-assisted developed code using engineering equation solver softwa...
متن کامل