3D Analysis of Intensity-Modulated Radiation Therapy Quality Assurance Measurement using a 2D Diode Array

نویسندگان

  • M. Lawrence
  • T. Cullip
  • L. Potter
  • S. Wang
  • Z. Xu
  • K. Burkhardt
  • S. Chang
چکیده

Intensity-modulated radiation therapy (IMRT) quality assurance (QA) is often performed using a 2D device and compares measured and computed fluence maps to determine if a field passes or fails certain dose and position criteria. The effects of a measured deviation to the 3D patient spatial dosimetry and dose volume histogram (DVH) are largely unknown because they cannot be analyzed using commercial 2D array IMRT QA systems. We report an in-house treatment planning system (TPS) PLanUNC based 3D IMRT QA analysis approach that has been used in our institution for the past ten years when 2D fluence map IMRT QA failed. In this approach the measured 2D fluence maps are imported back to PLanUNC and used to re-compute 3D patient dosimetry including DVHs. The 2D fluence map IMRT QA criteria is that the measured dose for 95% of the detectors is within 5% of the planned dose, and that the distance-to-agreement be within 4mm (5%/4mm). 22 IMRT plans that had at least one field fail initial QA using MapCHECK 2 are examined using our 3D QA approach. The DVH analysis shows that 19/22 plans that failed initial QA were within 2% of the planned target and critical structure DVHs. 3/22 IMRT plans were found to have DVH difference greater than 2%. The 3D analysis of 2D IMRT QA result shows that when a fluence map QA fails for a single field, often it is clinically insignificant in terms of patient 3D dosimetry

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of gated volumetric modulated arc therapy

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

متن کامل

A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery.

An analysis is made of a two-dimensional array of diodes that can be used for measuring dose generated in a plane by a radiation beam. This measuring device is the MapCHECK Model 1175 (Sun Nuclear, Melbourne, FL). This device has 445 N-type diodes in a 22 x 22 cm2 2-D array with variable spacing. The entire array of diodes is easily calibrated to allow for measurements in absolute dose. For IMR...

متن کامل

Incorporation of gantry angle correction for 3D dose prediction in intensity-modulated radiation therapy

Pretreatment dose verification with beam-by-beam analysis for intensity-modulated radiation therapy (IMRT) is commonly performed with a gantry angle of 0° using a 2D diode detector array. Any changes in multileaf collimator (MLC) position between the actual treatment gantry angle and 0° may result in deviations from the planned dose. We evaluated the effects of MLC positioning errors between th...

متن کامل

Patient Specification Quality Assurance for Glioblastoma Multiforme Brain Tumors Treated with Intensity Modulated Radiation Therapy

The aim of this study was to evaluate the significance of performing patient specification quality assurance for patients diagnosed with glioblastoma multiforme treated with intensity modulated radiation therapy. The study evaluated ten intensity modulated radiation therapy treatment plans using 10 MV beams, a total dose of 60 Gy (2 Gy/fraction, five fractions a week for a total of six weeks tr...

متن کامل

Dosimetric verification for intensity-modulated arc therapy plans by use of 2D diode array, radiochromic film and radiosensitive polymer gel

Several tools are used for the dosimetric verification of intensity-modulated arc therapy (IMAT) treatment delivery. However, limited information is available for composite on-line evaluation of these tools. The purpose of this study was to evaluate the dosimetric verification of IMAT treatment plans using a 2D diode array detector (2D array), radiochromic film (RCF) and radiosensitive polymer ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010