Increasing abdominal pressure with and without PEEP: effects on intra-peritoneal, intra-organ and intra-vascular pressures

نویسندگان

  • Stephan M Jakob
  • Rafael Knuesel
  • Jyrki J Tenhunen
  • Richard Pradl
  • Jukka Takala
چکیده

BACKGROUND Intra-organ and intra-vascular pressures can be used to estimate intra-abdominal pressure. The aim of this prospective, interventional study was to assess the effect of PEEP on the accuracy of pressure estimation at different measurement sites in a model of increased abdominal pressure. METHODS Catheters for pressure measurement were inserted into the stomach, urinary bladder, peritoneal cavity, pulmonary artery and inferior vena cava of 12 pigs. The pressures were recorded simultaneously at baseline, during 10 cm H20 PEEP, external abdominal pressure (7 kg weight) plus PEEP, external abdominal pressure without PEEP, and again under baseline conditions. RESULTS (MEAN +/- SD): PEEP alone increased diastolic pulmonary artery and inferior vena cava pressure but had no effect on the other pressures. PEEP and external abdominal pressure increased intraperitoneal pressure from 6 +/- 1 mm Hg to 9 +/- 2 mm Hg, urinary bladder pressure from 6 +/- 2 mm Hg to 11 +/- 2 mm Hg (p = 0.012), intragastric pressure from 6 +/- 2 mm Hg to 11 +/- 2 mm Hg (all p <or= 0.001), and inferior vena cava pressure from 11 +/- 4 mm Hg to 15 +/- 4 mm Hg (p = 0.01). Removing PEEP and maintaining extraabdominal pressure was associated with a decrease in pulmonary artery diastolic but not in any of the other pressures. There was a significant correlation among all pressures. Bias (-1 mm Hg) and limits of agreement (3 to -5 mm Hg) were similar for the comparisons of absolute intraperitoneal pressure with intra-gastric and urinary bladder pressure, but larger for the comparison between intraperitoneal and inferior vena cava pressure (-5, 0 to -11 mm Hg). Bias (0 to -1 mm Hg) and limits of agreement (3 to -4 mm Hg) for pressure changes were similar for all comparisons CONCLUSIONS Our data suggest that pressure changes induced by external abdominal pressure were not modified by changing PEEP between 0 and 10 cm H20.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Author's response to reviews Title: Increasing abdominal pressure with and without PEEP: Effects on intra-peritoneal, intra-organ and intra-vascular pressures Authors:

the type of investigation is missing. So is the animal species used. Response The type of investigation has been added to the abstract: “The aim of this prospective, interventional study was to assess whether using additional PEEP to increase abdominal pressure interferes with the accuracy of pressure estimation at different measurement sites.” The animal species is mentioned in the methods par...

متن کامل

Comparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma

Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...

متن کامل

Commonly applied positive end-expiratory pressures do not prevent functional residual capacity decline in the setting of intra-abdominal hypertension: a pig model

INTRODUCTION Intra-abdominal hypertension is common in critically ill patients and is associated with increased morbidity and mortality. The optimal ventilation strategy remains unclear in these patients. We examined the effect of positive end-expiratory pressures (PEEP) on functional residual capacity (FRC) and oxygen delivery in a pig model of intra-abdominal hypertension. METHODS Thirteen ...

متن کامل

Interaction Between Intra-Abdominal Pressure and Positive-End Expiratory Pressure

OBJECTIVE The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positive-End Expiratory Pressure level of zero and 10 cm H2O. The measurements were repeated after plac...

متن کامل

Intra-abdominal pressure and associated factors in patients admitted to critical care ‎units

Introduction: Despite the impact of increased abdominal hypertension on organ dysfunction and &lrm;increased mortality, data on the frequency and its related risk factors in critical care unit does not &lrm;seem enough. While studies have shown that patients&rsquo; intra-abdominal pressure measured at &lrm;admission to intensive care unit can serve as an independent prognostic factor for mortal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010