Heart-on-a-Chip: A Closed-loop Testing Platform for Implantable Pacemakers

نویسندگان

  • Zhihao Jiang
  • Sriram Radhakrishnan
  • Varun Sampath
  • Shilpa Sarode
  • Rahul Mangharam
چکیده

Implantable cardiac pacemakers restore normal heart rhythm by delivering external electrical pacing to the heart. The pacemaker software is life-critical as the timing of the pulses determine its ability to control the heart rate. Recalls due to software issues have been on the rise with the increasing complexity of pacing algorithms. Open-loop testing remains the primary approach to evaluate the safety of pacemaker software. While this tests how the pacemaker responds to stimulus, it cannot reveal pacemaker malfunctions which drive the heart into an unsafe state over multiple cycles. To evaluate the safety and efficacy of pacemaker software we have developed a heart model to generate different heart conditions and interact with real pacemakers. In this paper, we introduce the closed-loop testing platform which consists of a programmable hardware implementation of the heart that can interact with a commercial pacemaker in closed-loop. The heart-on-a-chip implementation is automatically generated from the Virtual Heart Model in Simulink which models different heart conditions. We describe a case study of Endless Loop Tachycardia to demonstrate potential closed-loop pacemaker malfunctions which inappropriately increase the heart rate. The test platform is part of our model-based design framework for verification and testing of medical devices with the patient-in-the-loop.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyber-Physical Modeling of Implantable Cardiac Medical Devices

The design of bug-free and safe medical device software is challenging, especially in complex implantable devices that control and actuate organs in unanticipated contexts. Safety recalls of pacemakers and implantable cardioverter defibrillators between 1990 and 2000 affected over 600,000 devices. Of these, 200,000 or 41%, were due to firmware issues and their effect continues to increase in fr...

متن کامل

Abstraction Trees for Closed-Loop Model Checking of Medical Devices

ion Trees for Closed-Loop Model Checking of Medical Devices Zhihao Jiang, Houssam Abbas, Pieter J. Mosterman, and Rahul Mangharam 1 Department of Electrical and Systems Engineering, University of Pennsylvania 2 School of Computer Science, McGill University, Canada 3 MathWorks, USA Abstract. This paper proposes a methodology for closed-loop model checking of medical devices, and illustrates it w...

متن کامل

Towards the Emulation of the Cardiac Conduction System for Pacemaker Testing

The heart is a vital organ that relies on the orchestrated propagation of electrical stimuli to coordinate each heart beat. Abnormalities in the heart’s electrical behaviour can be managed with a cardiac pacemaker. Recently, the closed-loop testing of pacemakers with an emulation (real-time simulation) of the heart has been proposed. An emulated heart would provide realistic reactions to the pa...

متن کامل

Platform for Closed Loop Neuromodulation Based on Dual Mode Biosignals

Closed loop neuromodulation, where the stimulation is controlled autonomously based on physiological events, has been more effective than open loop techniques. In the few existing closed loop implementations which have a feedback, indirect non-neurophysiological biomarkers have been typically used (e.g. heart rate, stomach distension). Although these biomarkers enable automatic initiation of ne...

متن کامل

Closed Loop Stimulation and Evaluation of the Effect of the Autonomic Nervous System Using Heart Rate Variability

Rate-Responsive Pacemakers Rate-responsive pacemakers are widely used to treat chronotropic incompetence as well as complete atrioventricular (AV) block or sinus node disease. Of the several sensor concepts that have been evaluated since 1980, the activity sensor (accelerometer) and two physiologic models (minute ventilation and QT interval) have been predominantly used in clinical practice. So...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014