Implications of complex anatomical junctions on conductance catheter measurements of coronary arteries.

نویسندگان

  • Hyo Won Choi
  • Zhen-Du Zhang
  • Neil D Farren
  • Ghassan S Kassab
چکیده

In vivo, the position of the conductance catheter to measure vessel lumen cross-sectional area may vary depending on where the conductance catheter is deployed in the complex anatomical geometry of arteries, including branches, bifurcations, or curvatures. The objective here is to determine how such geometric variations affect the cross-sectional area (CSA) estimates obtained using the cylindrical model. Computer simulations and in vitro and in vivo experiments were used to assess how the electric field and associated CSA measurement accuracy are affected by three typical in vivo conditions: 1) a vessel with abrupt change in lumen diameter (e.g., transition from aorta to coronary ostia); 2) a vessel with a T-bifurcation or a Y-bifurcation; and 3) a vessel curvature, such as in the right coronary artery, aorta, or pulmonary artery. The error in diameter from simulation results was shown to be relatively small (<7%), unless the detection electrodes were placed near the junction between two different lumen diameters or at a bifurcation junction. Furthermore, the present findings show that the effect of misaligned catheter-vessel geometrical configuration and vessel curvature on measurement accuracy is negligible. Collectively, the findings support the accuracy of the conductance method for sizing blood vessels, despite the geometric complexities of the cardiovascular system, as long as the detection electrodes are not placed at a large discontinuity in diameter or at bifurcation junctions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conductance catheter measurements of lumen area of stenotic coronary arteries: theory and experiment.

An injection of saline solution is required for the measurement of vessel lumen area using a conductance catheter. The injection of room temperature saline to displace blood in a vessel inevitably involves mass and heat transport and electric field conductance. The objective of the present study is to understand the accuracy of conductance method based on the phenomena associated with the salin...

متن کامل

Impact of surrounding tissue on conductance measurement of coronary and peripheral lumen area.

Parallel conductance (electric current flow through surrounding tissue) is an important determinant of accurate measurements of arterial lumen diameter, using the conductance method. The present study is focused on the role of non-uniform geometrical/electrical configurations of surrounding tissue, which are a primary source of electric current leakage. Computational models were constructed to ...

متن کامل

TRANSLATIONAL PHYSIOLOGY New method to measure coronary velocity and coronary flow reserve

Zhang ZD, Svendsen M, Choy JS, Sinha AK, Huo Y, Yoshida K, Molloi S, Kassab GS. New method to measure coronary velocity and coronary flow reserve. Am J Physiol Heart Circ Physiol 301: H21–H28, 2011. First published May 6, 2011; doi:10.1152/ajpheart.00080.2011.—Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the...

متن کامل

New method to measure coronary velocity and coronary flow reserve.

Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the reproducibility and accuracy of intravascular conductance catheter-based method for measurements of baseline and hyperemic coronary flow velocity (and hence CFR). The absolute coronary blood velocity was determined by measuring the time of transit of a saline ...

متن کامل

Novel method for measurement of medium size arterial lumen area with an impedance catheter: in vivo validation.

There is no doubt that the transformation of a cardiac catheter into a conductance catheter that allows reliable and accurate assessment of lumen cross-sectional area (CSA) will provide a powerful diagnostic and treatment tool for the invasive cardiologist. The objective of this study was to develop a method based on the impedance catheter that allows accurate and reproducible measurements of C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 114 5  شماره 

صفحات  -

تاریخ انتشار 2013