Optimal System Frequency Response Model and UFLS Schemes for a Small Receiving-End Power System after Islanding

نویسندگان

  • Deyou Yang
  • Guowei Cai
چکیده

Large frequency deviations after islanding are exceedingly critical in small receiving-end power systems. The under-frequency load shedding (UFLS) scheme is an efficient protection step for preventing system black outs. It is very important to get an exact model to design the UFLS schemes. In this paper, an optimization model to achieve the system frequency response (SFR) model either from the full-scale power system or from test records was proposed. The optimized SFR model took into account the response of governors-prime movers and the dynamic characteristics of loads developed in the modern power system. Then the UFLS schemes were designed via the optimized SFR model and particle swarm optimization (PSO) method. The time-domain simulation with the actual small receiving-end power system was presented to investigate the validity of the presented model and the developed technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بهبود پایداری شبکه قدرت با روش جدید حذف بار ترکیبی

Power system blackouts have become a serious problem for electric utilities especially in recent years. Different forms of system instability have emerged in recent blackouts, such as voltage instability and frequency instability. To counteract each form of system instability, special algorithms have been designed in the protection system, e.g. Under Frequency Load Shedding (UFLS) and Under Vol...

متن کامل

ارائه الگوریتم حذف بار وفقی جهت حفاظت سیستم قدرت در مقابل حوادث ترکیبی منجر به خاموشی سراسری

In recent years several catastrophic power systems blackouts have occurred worldwide. Various reasons have been declared for these failures. Economical limitations due to power system restructuring restrictions, inadvertent operation of protective relays and inefficient design of conventional load shedding schemes are of the most important reasons causing these blackouts. In fact, due to both e...

متن کامل

Optimal Setting Sor Under Frequency Load Shedding Relays Using Mixed Integer Linear Programming

After occurrence of some disturbances in power system that causes the sever imbalance between generation power and electrical load, the power system frequency begins to decrease. To prevent power system frequency instability and stop the frequency decay below the power system allowable frequency limitation, load shedding schemes should be utilized by applying under frequency load shedding relay...

متن کامل

Under-Frequency Load Shedding (UFLS) Schemes – A Survey

The Under-frequency Load Shedding (UFLS) scheme has been used by utility companies around the world to mitigate frequency drop caused by simultaneous or cascading tripping of transmission lines and/or generators in a power system. In the effort to devise an optimal load shedding scheme, it is imperative that investigations are done on the many factors that may affect the response of the scheme ...

متن کامل

An Improved Under-Frequency Load Shedding Scheme in Distribution Networks with Distributed Generation

When a distribution network consisting of Distributed Generations (DGs) is disconnected from upstream network, the system may be exposed to severe power imbalance. In order to prevent the damage of power plants, frequency relays operate and remove DGs from the network. In contrast to traditional methods, the main objective in new methods is to keep DG units in service in the islanded distributi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017