Comparison of Arterial Repair through the Suture, Suture with Fibrin or Cyanoacrylate Adhesive in Ex-Vivo Porcine Aortic Segment

نویسندگان

  • Marcus Vinicius H. de Carvalho
  • Evaldo Marchi
  • Edmir Américo Lourenço
چکیده

INTRODUCTION Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. OBJECTIVE To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. METHODS 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. RESULTS In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002). In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002). Intraluminal adhesive penetration has not been noticed. CONCLUSION There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A single-surgeon randomized trial comparing sutures, N-butyl-2-cyanoacrylate and human fibrin glue for mesh fixation during primary inguinal hernia repair.

BACKGROUND We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. METHODS A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent a plug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n =...

متن کامل

Effectiveness and biocompatibility of a novel biological adhesive application for repair of meniscal tear on the avascular zone.

We have investigated the effectiveness and safety of a newly developed biological adhesive for repair of meniscal tear. The adhesive was composed of disuccinimidyl tartrate (DST) as a crosslinker and human serum albumin (HSA) as a hardener. To determine adequate concentration, bonding strength was measured using a tensiometer 5 min after applying the adhesive on the avascular zone tear of porci...

متن کامل

Shear lag sutures: Improved suture repair through the use of adhesives.

Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby s...

متن کامل

Comparison of Tensile Strength of Fibrin Glue, 2-Octyl Cyanoacrylate, Liquid Ocular Bandage, and Conventional Nylon 10-0 Sutures in Corneal Laceration Repair in an Animal Model

Objective: To compare the tensile strength of fibrin glue, 2-octyl cyanoacrylate, and liquid ocular bandage to conventional nylon 10-0 sutures in sealing central linear corneal lacerations. Methods: An experimental in-vitro study was performed on 74 porcine eyes. A 27-gauge needle connected to an infusion system with balanced salt solution was inserted into the anterior chamber and the bottle h...

متن کامل

Comparison of tensile strength of fibrin glue and suture in microflap closure.

OBJECTIVES/HYPOTHESIS Suture closure and fibrin glue placement have been advocated as alternatives to healing by secondary intention. The aim of this study was to examine the tensile strength of these microflap closure techniques. STUDY DESIGN Basic research. METHODS Three pairs of excised bovine true vocal folds underwent microflap creation and closure by either single 6-0 polyglactin sutu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2017