Image-quality optimization for dual energy computed tomography (DECT) three-material decomposition OPTIMIZACIÓN DE LA CALIDAD DE LA IMAGEN PARA LA SEPARACIÓN DE TRES MATERIALES UTILIZANDO LA TOMOGRAFÍA COMPUTARIZADA DE DOS ENERGÍAS (TCDE)

نویسنده

  • Carolina Arboleda
چکیده

Dual energy computed tomography, which consists of the acquisition of two images of a given region of interest using two different x-ray energies, has been used to decompose images. For example, it has been proposed to estimate the degree of stenosis of blood vessels with calcifi ed plaques. Pragmatic realities, though, such as beam hardening, scattered radiation and mostly quantum noise, reduce the ideal of a perfect decomposition. In this study, a dual energy separation method for iodinated contrast media, cortical bone and soft tissue was implemented; afterwards, it was tested in simulated noiseless and noisy situations. The noise propagation was modeled mathematically, and an image-quality optimization technique regarding the right distribution of radiation dose between the high and low energy images was proposed. The results obtained suggest that in the absence of noise and using mono-energetic beams, an accurate separation is possible, but when noise is added and poly-chromatic spectra used this decomposition becomes more challenging. Keywords— Dual energy computed tomography, Image-quality optimization technique, Linear attenuation coeffi cient, Material-decomposition algorithms, Noise propagation, Radiation dose. Resumen— La tomografía computarizada de dos energías, que consiste en la adquisición de dos imágenes de una región de interés dada usando rayos X de dos energías distintas, ha sido utilizada para descomponer imágenes. Por ejemplo, esta técnica ha sido propuesta para estimar el grado de estenosis de vasos sanguíneos obstruidos con placas de calcio. Sin embargo, fenómenos como el endurecimiento del rayo, la radiación dispersada y principalmente el ruido cuántico, impiden que esta separación sea perfecta. En este estudio, se implementó un método de separación de medio de contraste yodado, tejido blando y hueso cortical; este se evaluó en simulaciones, tanto en presencia como en ausencia de ruido. Posteriormente, se modeló matemáticamente la propagación del ruido y, con base en los resultados de estos modelos, se propuso una técnica de optimización de la imagen basada en la distribución adecuada de la dosis de radiación entre las imágenes de energías alta y baja. Los resultados evidencian que en ausencia de ruido y con rayos mono-energéticos, es posible obtener una separación precisa, pero cuando se adiciona ruido a las imágenes y se trabaja con espectros policromáticos, la descomposición resulta más complicada. Palabras clave— Tomografía computarizada de dos energías, Técnicas de optimización de la calidad de la imagen, Coefi ciente de atenuación lineal, Algoritmos de separación de materiales, Propagación del ruido, Dosis de radiación. 34 REVISTA INGENIERÍA BIOMÉDICA

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peritoneal Dialysis

La,dialyse peritoneale constitue une methode d,epuration extra-renale simple,efficqCe et d,un prix de revient modere.  La dialyse peritoneale,ne necestite aueune­instalation complexe,peut-etre consideree comme une methode de reanimation non specialisedont la vulga­rosation doit permettre:  De traiter surplace d,une maniere intensive et prophylactique les nombreuses insuffisances renales aiPue...

متن کامل

Enfoque geométrico para la estimación del peso del fruto mango de azúcar mediante procesamiento digital de imágenes

The accu r ate measur ement of the fr uits’ physical features, such as weight and maturation­level, is a typical and imp or ta n t p r ocedur e in ma ny ind ustr ia l p r ocesses a imed to classification and selection of quality products for the export. This paper descr ibes an automatic geometr ic procedure toward to th e weigh t est ima t ion of t he M a ng...

متن کامل

Total Flavonoid Determination for the Quality Control of Aqueous Extractives from Phyllanthus niruri L

The purpose of this study has been the development of an adequate methodology for the quality control of Phyllanthus niruri aqueous extracts. The assay method was tested, with various modifications, to determine its suitability for the quantitative determination of total flavonoids within the crude drug raw material and aqueous extracts. The assay technique for such chemical group is based on t...

متن کامل

Manejo de Objetos en un Editor Gráfico en Tres Dimensiones

Para la elaboración del programa, se optó por implementar un ambiente gráfico utilizando lenguaje C++ orientado a objetos. Es importante hacer notar que el programa fue elaborado en un ambiente DOS y no para Windows, debido a que la generación de un ambiente gráfico propio nos permitirá dominar la técnica de manejo de ventanas, menús, etc.; elementos que por estar definidos para Windows, restri...

متن کامل

Selective Celiac Angiography in Hepatic Hydatid Cyst and Comparison with Scintigraphy

This article was presented by the author at the Third Iranian Congress of Radiology - University of Isfahan. Les explorations arteriographiques des kystes hydatique du foie et sa comparaison avec Ia scintigraphie hepatique L' auteur present quatre cas de quarante six cas d'angiographie coeliaque et mesentrique sup2-rieure en portant son attention sur les resultats obtenus de cet examen et de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009