Organ doses, detriment and genetic risk from interventional vascular procedures in Málaga (Spain).

نویسندگان

  • R Ruiz-Cruces
  • M Perez-Martinez
  • I Tort Ausina
  • V Muñoz
  • M Martinez-Morillo
  • A Diez de los Ríos
چکیده

Nowadays, the radiological risk from simple X-ray procedures is well known. The purpose of this work has been to estimate the population risk from digital angiographic and interventional procedures and to compare it with the one from simple procedures in the same population. The population risk has been estimated according to the following quantities: genetically significant dose, somatic significant dose, collective effective dose, annual per caput effective dose and detriment. These have been estimated from dose area product and organ dose. Organ dose values were estimated with the Eff-Dose software. A population of 605410 people were included in the study. In 1996, 1312 patients were to digital interventional vascular procedures in Malaga, and 159 of them were selected in this research project to obtain the dose area product and organ dose. The results obtained for the quantities evaluated are: genetically significant dose, 4.1 microGy; somatic significant dose, 0.9 mSv; collective effective dose, 11.65 person-Sv: annual per caput effective dose, 0.02 mSv and detriment, 0.65 radiogenic cancers per year. These procedures supply a high radiation dose, so they should have a greater contribution to population dose and risk than simple examinations. However, our results indicate just the opposite.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective doses in radiology and diagnostic nuclear medicine: a catalog.

Medical uses of radiation have grown very rapidly over the past decade, and, as of 2007, medical uses represent the largest source of exposure to the U.S. population. Most physicians have difficulty assessing the magnitude of exposure or potential risk. Effective dose provides an approximate indicator of potential detriment from ionizing radiation and should be used as one parameter in evaluati...

متن کامل

Excess Cancer Risk Assessment from Some Common X-Ray Examinations in Sabzevar County

Introduction: Nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. Using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. X-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. These effects obey the LNT hypothesis that occur at lo...

متن کامل

Heavy metal pad shielding during fluoroscopic interventions.

Significant direct and scatter radiation doses to patient and physician may result from routine interventional radiology practice. A lead-free disposable tungsten antimony shielding pad was tested in phantom patients during simulated diagnostic angiography procedures. Although the exact risk of low doses of ionizing radiation is unknown, dramatic dose reductions can be seen with routine use of ...

متن کامل

Evaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran

Introduction The purpose of this study was to estimate organ and effective doses in patients undergoing some common X-ray examinations in Sabzevar, Iran. The effective dose is one of the best parameters for describing the amount of radiation dose received by a patient undergoing any diagnostic X-ray examination. The public dose from X-ray examinations depends on various factors, and its contrib...

متن کامل

Dose Reconstruction in Radiological Exposures

Dose reconstruction is a comprehensive analysis of the exposure received by individuals in the vicinity of facilities that release contaminants to the environment (i.e., real doses to real people).Performing dose reconstruction analyses which are extremely important elements for improving efficiency in radiological emergencies and accidents have been studied in this paper. For dose reconstructi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of radiology

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2000