Enzymatic kinetic rate and end-point analyses of substrate, by use of a GeMSAEC fast analyzer.
نویسندگان
چکیده
Enzymatic substrate analysis is an attractive means of analysis in cliniaI chemistry because of its sensitivity and specificity. The GeMSAEC Fast Analyzer, in conjunction with a small computer, provides a means of performing routine enzymatic substrate analysis and offers the following advantages: (a) selectivity of approaches to enzymatic analysis, i.e., end-point or kinetic; (b) essentially parallel analyses of multiple samples, yielding a unique method for performing kinetic fixed-time analysis; (c) on-line data reduction, resulting in rapid calculation and output of results and the minimization of data handling errors; and (d) a small reagent volume per test (400 ILl), which reduces the cost of analysis. The analysis of substrate with enzymatic end-point and kinetic procedures is examined by use of a computerinterfaced Fast Analyzer. Computer programs were written to facilitate this study. Glucose (hexoki. nase/GPD), urea (urease/GMD), and uric acid (uricase) have been used as examples in eValuating both end-point and kinetic analyses. The advantages and limitations of each type of analysis are presented, with the emphasis being placed on enzymatic substrate analysis and means by which the computer-interfaced Fast Analyzer can facilitate both end-point and kinetic analyses.
منابع مشابه
Higher copper concentrations in serum than in plasma.
CLIN. CHEM. 20/9, 1233-1234(1974) 3. Praetorius, E., and Paulsen, H., Enzymatic determination of uric acid with detailed directions. Scand. J. Clirz. Lab. Invest. 5, 273 (1953). 4. Feichtmeir, T. V., and Wrenn, H. T., Direct determination of uric acid using unease. Amer. J. Clin. Pathol. 25,833 (1955). 5. Liddle, L., Seegniiller, J. E., and Laster, L., The enzymatic spectrophotometric method fo...
متن کاملAutomated sample-reagent loader for use with the GeMSAEC fast analyzer.
The GeMSAEC3 Fast Analyzer, recently developed at the Oak Ridge National Laboratory (1-9), gives promise of increasing both the rate at which many clinical and biochemical analyses may be performed and their precision and accuracy. To do so, its sample analysis rate must be reasonable and economical. Aside from modification of the GeMSAEC analytical module per se [e.g., a previous paper (9) rep...
متن کاملFluorometric fast analyzer: some applications to fluorescence measurements in clinical chemistry.
A fluorometric Fast Analyzer has been developed, based on the GeMSAEC Fast Analyzer principle. Potential applications of a multiple-cuvet fluorometric analyzer are considered. A primary concern must be referencing enzyme activity assays and enzymic substrate analyses. Once adequate referencing techniques are developed, adaptation of analyses can proceed. The advantages of fluorescence procedure...
متن کاملFeasibility of multiple simultaneous enzyme assays, for diagnostic purposes, with the GeMSAEC fast analyzer.
The GeMSAEC fast analyzer provides the clinical chemistry laboratory with an analytical instrument that can be used to perform large numbers of kinetic enzyme analyses. Precise enzyme-rate analyses can be done routinely, on a large scale, and at a decreased cost per test. Improved precision in analyses of enzymes should provide more reliable data because analytical variation is lessened. We hav...
متن کاملMeasurement of antitryptic activity of serum with a centrifugal analyzer.
The Selected Method [Clin. Chem. 20, 396 (1974)] for the enzymatic assay of alpha1-antitrypsin in serum has been adapted for use with the E.N.I.-GEMSAEC. With alpha-N-benzoyl-D,L-arginine-p-nitroanilide as substrate, the difference between the tryptic activity measured with and without addition of serum in the same run has been used to calculate the trypsin-inhibitory capacity. The rate of incr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 18 8 شماره
صفحات -
تاریخ انتشار 1972