Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis.

نویسندگان

  • Di Wu
  • Yan Wang
  • Lin Zhang
  • Shengsheng Wei
  • Xin Tang
چکیده

PURPOSE To compare the biomechanical properties of the cornea after small-incision lenticule extraction (lenticule extraction group) with those after femtosecond laser-assisted laser in situ keratomileusis (femtosecond LASIK group). SETTING Tianjin Eye Hospital & Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Medical University, Tianjin, China. DESIGN Prospective comparative case series. METHODS Corneal hysteresis (CH), the corneal resistance factor (CRF), and 37 other biomechanical waveform parameters were quantitatively assessed with the Ocular Response Analyzer preoperatively and 1 week and 1, 3, and 6 months postoperatively. RESULTS Each group comprised 40 eyes. The decrease in CH and the CRF was statistically significant 1 week postoperatively compared with preoperatively in both groups (P<.0001). However, the CH and CRF values in the lenticule extraction group were significantly higher than those in the femtosecond LASIK group 3 months and 6 months postoperatively (P<.032). The residual stromal thickness index versus the CRF and CH and the planned lenticule thickness versus the change in central corneal thickness were statistically significant in the lenticule extraction group (r = 0.388 to 0.950, P<.018); no significant correlation was found in the femtosecond LASIK group. In the waveform analysis of the lenticule extraction group, 28 of the 37 biomechanical waveform parameters differed significantly between preoperative values and postoperative values (P<.035). CONCLUSIONS Both small-incision lenticule extraction and femtosecond laser-assisted LASIK can cause biomechanical changes in the cornea. However, changes in the cornea's viscoelastic properties were less after lenticule extraction than after LASIK. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal biomechanics after small-incision lenticule extraction versus Q-value–guided femtosecond laser-assisted in situ keratomileusis

PURPOSE The aim of this study was to compare the changes in corneal biomechanical properties following small-incision lenticule extraction (SMILE) versus Q-value-guided femtosecond laser-assisted in situ keratomileusis (Q-FS-LASIK). METHODS In this prospective comparative study, patients with a sphere plus cylinder measurement of less than -10.00 D and cylinder measurement of less than -5.00 ...

متن کامل

A Review of Corneal Biomechanics after LASIK and SMILE and the Current Methods of Corneal Biomechanical Analysis

Corneal refractive surgeries for the correction of myopia, hyperopia, astigmatism and hyperopia are quick and effective procedures, and have been growing in popularity over the last two decades. However, post-surgery corneal ectasia remains one of the most feared surgical complications. This is where the biomechanical integrity of the cornea begins to fail, with progressive thinning of the stro...

متن کامل

Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis

BACKGROUND Evaluating the corneal biomechanical changes using the Ocular Response Analyzer and the Corvis ST in eyes with incision lenticule extraction (SMILE) and laser assisted in situ keratomileusis (LASIK). METHODS This is a retrospective study that included 50 eyes equally divided into two groups. The first group included eyes that underwent SMILE procedure using VisuMax® 500 kHz laser s...

متن کامل

Comparison of different femtosecond laser refractive surgeries on higher-order aberrations

This study aimed to investigate the effects of femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) on higher-order aberrations in patients. 56 cases (112 eyes) undergoing refractive surgery in our hospital were selected in this study, all patients were randomly divided into femtosecond laser-assisted in situ keratomileusis group (LASIK gr...

متن کامل

Efficacy, safety, predictability, contrast sensitivity, and aberrations after femtosecond laser lenticule extraction.

PURPOSE To compare femtosecond lenticule extraction and small-incision lenticule extraction to treat moderate to high myopia. SETTING Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. DESIGN Prospective clinical single-masked paired-eye study. METHODS An intrastromal lenticule was cut by a femtosecond laser and manually extracted. In femtosecond lenticule extractio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 40 6  شماره 

صفحات  -

تاریخ انتشار 2014