Evaluation of four assay methods for determination of tobramycin in human serum.

نویسندگان

  • W J Acton
  • O M Van Duyn
  • L V Allen
  • D J Flournoy
چکیده

Four assay procedures for tobramycin in serum--enzyme immunoassay (I), substrate-labeled fluorescent immunoassay (II), radioimmunoassay (III), and bioassay (IV)--were compared and evaluated by replicate and analytical recovery studies. I and II were about 50% more precise than III and IV. II was substantially more nearly accurate than the other methods and also gave the best reproducibility (correlation coefficient 0.992 between-day). The least expensive method was IV. Ease of handling favored I and II. Overall, we find II to be the most acceptable procedure for use in the clinical laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of an artificial matrix to replace human standards of prostate specific antigen IRMA assay kit [Persian]

  Introduction: Prostate specific antigen (PSA) is one of the most sensitive markers for diagnosis of prostate cancer. Immunoradiometric kit (IRMA) is a common and sensitive method for determination of PSA in clinical laboratories. This kit has four major components: solid phase coated with monocolonal antibody, pair antibody labelled with I-125, series of standards i...

متن کامل

Preparation of prostate specific antigen standards for immunoradiometric assay

Background: Immunoradiometric assay is one of the most common and precise methods for determination of prostate specific antigen (PSA) in clinical laboratories. Usual use of human serum in routine assays has many disadvantages such as easy contamination and precipitation, instability and unavailability. Thus in order to avoid these problems the artificial matrix was used which acts sim...

متن کامل

Evaluation of four gentamicin and tobramycin assay procedures for clinical laboratories.

Accuracy, precision, and clinical laboratory utility of the TDX (Abbott Laboratories), Auto-ICS (Beckman Instruments, Inc.), COBAS-Bio (Roche Analytical Instruments, Inc.) with reagent kits (Syva), and EMIT (Syva) for gentamicin and tobramycin serum assay were assessed. TDX, COBAS-Bio, and EMIT analytical systems showed a proportional bias of less than 10% for recovery studies and a coefficient...

متن کامل

Serum standards for the bioassay of aminoglycosides in cerebrospinal fluid.

Four diluents were compared as reference standards for the assay of gentamicin in cerebrospinal fluid (CSF): human CSF, human serum, distilled water, and 150 mmol NaCl/4.5 mmol CaCl2. Standards prepared in pooled human serum were the best alternative to CSF for the assay of gentamicin and were also useful for the assay of tobramycin, netilmicin, amikacin, and sisomicin. The pH (6.0-9.8) of CSF ...

متن کامل

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 1982