Non-cycloplegic screening for amblyopia via refractive findings with the Nikon Retinomax hand held autorefractor in 3 year old kindergarten children.
نویسندگان
چکیده
AIMS To assess non-cycloplegic screening for amblyopia with the hand held Nikon Retinomax autorefractor in 3 year old kindergarten children. METHODS 427 three year old children were examined in kindergarten with the Retinomax without cycloplegia. A gold standard was established in all children by two orthoptic examinations in kindergarten. If there were missing, abnormal, or inconsistent findings, children were referred for ophthalmological examination. If, by the ophthalmological examination, a new case of amblyopia requiring treatment was diagnosed, the gold standard was set "positive." RESULTS In 404 children the gold standard was obtained. 10 children (2.5%) had a "positive" gold standard of unknown and untreated amblyopia. Screening sensitivity was 0.80, specificity 0.58, accuracy 0.58, and the likelihood ratio 1.89. CONCLUSION Non-cycloplegic refractive screening with the Retinomax led to many false positive referrals due to instrument myopia and "inconclusive" results. Hence specificity, accuracy, and the likelihood ratio were too low to conduct screening effectively.
منابع مشابه
Reproducibility and accuracy of measurements with a hand held autorefractor in children.
AIM To determine reproducibility and accuracy of the Nikon Retinomax autorefractor when used with children who were made cycloplegic. METHODS Autorefraction and retinoscopy or subjectively refined retinoscopy (where, under the patient's direction, the refraction was varied until the best visual acuity was achieved) were performed on the right eye of 47 children, age 11-93 months. Autorefracti...
متن کاملScreening for abnormal levels of hyperopia in children: a non-cycloplegic method with a hand held refractor.
AIMS High hyperopia constitutes the majority of refractive errors in large scale visual screening at preschool ages. The authors aimed to assess the validity of the Retinomax hand held refractor to detect high hyperopia in a refractive screening performed without cycloplegia and carried out on children aged 9-36 months. They considered +1.5 D of manifest hyperopia to be the threshold value and ...
متن کاملEconomic evaluation of different methods of screening for amblyopia in kindergarten.
OBJECTIVE To compare the cost-effectiveness of 5 methods of screening for untreated amblyopia in kindergarten from a third-party-payer perspective: A) uncorrected monocular visual acuity testing with pass threshold > or =0.5 (20/40) and < or =1 line difference between eyes; B) same as A, but pass threshold > or =0.6 (20/32); C) same as A, plus cover tests and examination of eye motility and hea...
متن کاملScreening for refractive errors in children: accuracy of the hand held refractor Retinomax to screen for astigmatism.
AIMS To assess the reliability of the hand held automated refractor Retinomax in measuring astigmatism in non-cycloplegic conditions. To assess the accuracy of Retinomax in diagnosing abnormal astigmatism in non-cycloplegic refractive screening of children between 9 and 36 months. METHODS Among 1205 children undergoing a non-cycloplegic refractive screening with Retinomax, 299 (25%) had repea...
متن کاملFindings from the Vision in Preschoolers (VIP) Study.
The Vision in Preschoolers (VIP) Study Group conducted a multicenter, multidisciplinary, two-phase study to evaluate the performance of vision screening tests for identifying pre-school children with amblyopia, strabismus, significant refractive error, or unexplained reduced visual acuity (VA). The results of the VIP Study provide evidence-based guidelines for preschool vision screening. The be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 85 10 شماره
صفحات -
تاریخ انتشار 2001