Assessment and monitoring tumor vascularity with contrast-enhanced ultrasound maximum intensity persistence imaging.
نویسندگان
چکیده
OBJECTIVES Contrast-enhanced ultrasound imaging is increasingly being used in the clinic for assessment of tissue vascularity. The purpose of our study was to evaluate the effect of different contrast administration parameters on the in vivo ultrasound imaging signal in tumor-bearing mice using a maximum intensity persistence (MIP) algorithm and to evaluate the reliability of in vivo MIP imaging in assessing tumor vascularity. The potential of in vivo MIP imaging for monitoring tumor vascularity during antiangiogenic cancer treatment was further evaluated. MATERIALS AND METHODS In intraindividual experiments, varying contrast microbubble concentrations (5 × 10⁵, 5 × 10⁶, 5 × 10⁷, 5 × 10⁸ microbubbles in 100 μL saline) and contrast injection rates (0.6, 1.2, and 2.4 mL/min) in subcutaneous tumor-bearing mice were applied and their effects on in vivo contrast-enhanced ultrasound MIP imaging plateau values were obtained using a dedicated small animal ultrasound imaging system (40 MHz). Reliability of MIP ultrasound imaging was tested following 2 injections of the same microbubble concentration (5 × 10⁷ microbubbles at 1.2 mL/min) in the same tumors. In mice with subcutaneous human colon cancer xenografts, longitudinal contrast-enhanced ultrasound MIP imaging plateau values (baseline and at 48 hours) were compared between mice with and without antiangiogenic treatment (antivascular endothelial growth factor antibody). Ex vivo CD31 immunostaining of tumor tissue was used to correlate in vivo MIP imaging plateau values with microvessel density analysis. RESULTS In vivo MIP imaging plateau values correlated significantly (P = 0.001) with contrast microbubble doses. At 3 different injection rates of 0.6, 1.2, and 2.4 mL/min, MIP imaging plateau values did not change significantly (P = 0.61). Following 2 injections with the same microbubble dose and injection rate, MIP imaging plateau values were obtained with high reliability with an intraclass correlation coefficient of 0.82 (95% confidence interval: 0.64, 0.94). In addition, in vivo MIP imaging plateau values significantly correlated (P = 0.01; R² = 0.77) with ex vivo microvessel density analysis. Tumor volumes in treated and nontreated mice did not change significantly (P = 0.22) within 48 hours. In contrast, the change of in vivo MIP imaging plateau values from baseline to 48 hours was significantly different (P = 0.01) in treated versus nontreated mice. CONCLUSIONS Contrast-enhanced ultrasound MIP imaging allows reliable assessment of tumor vascularity and monitoring of antiangiogenic cancer therapy in vivo, provided that a constant microbubble dose is administered.
منابع مشابه
Quantification of tumor vascularity with contrast-enhanced sonography: correlation with magnetic resonance imaging and fluorodeoxyglucose autoradiography in an implanted tumor.
OBJECTIVE To correlate the quantitated tumor vascularity of implanted murine tumors as depicted by contrast-enhanced sonography with estimates made with magnetic resonance imaging and with estimates of the percentage of viable (metabolically active) tumor as depicted by fluorodeoxyglucose autoradiography. METHODS Implanted tumors in 10 mice were imaged with contrast-enhanced sonography, magne...
متن کاملContrast-Enhanced Dynamic MR Imaging of Uterine Fibroids as a Potential Predictor of Patient Eligibility for MR Guided Focused Ultrasound (MRgFUS) Treatment for Symptomatic Uterine Fibroids
Magnetic resonance-guided focused ultrasound surgery (MRgFUS) is a non-invasive treatment approach for symptomatic uterine fibroids. One imaging characteristic considered in selecting patients who may benefit from MRgFUS of their uterine fibroids is the signal intensity of the fibroid compared with surrounding myometrium on T2-weighted MR images. Previous reports suggest that hyper-intense fibr...
متن کامل3D imaging options and ultrasound contrast agents for the ultrasound assessment of pediatric rheumatic patients
The application of 3D imaging in pediatric rheumatology helps to make the assessment of inflammatory changes more objective and to estimate accurately their volume and the actual response to treatment in the course of follow-up examinations. Additional interesting opportunities are opened up by the vascularity analysis with the help of power Doppler and color Doppler in 3D imaging. Contrast-enh...
متن کاملUp-to-date Doppler techniques for breast tumor vascularity: superb microvascular imaging and contrast-enhanced ultrasound
Ultrasonographic Doppler techniques have improved greatly over the years, allowing more sophisticated evaluation of breast tumor vascularity. Superb microvascular imaging (SMI) and contrast-enhanced ultrasound (CEUS) with second-generation contrast agents are two representative up-to-date techniques. SMI is a sensitive Doppler technique that adopts an intelligent filter system to separate low-f...
متن کاملContrast-enhanced ultrasound performance of endometrioma treated with high-intensity focused ultrasound (HIFU)
Objective: This study is to investigate the application of contrast-enhanced ultrasound in assessment of High-Intensity Focused Ultrasound (HIFU) in treating endometrioma. Methods: Totally 60 patients with endometrioma were included in this study, who underwent HIFU in our hospital from June 2014 to July 2016. At 3 d before treatment, and at 1, 3, 6, and 12 months after treatment, contrast-enha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative radiology
دوره 46 3 شماره
صفحات -
تاریخ انتشار 2011