Automatic mode switching in atrial fibrillation
نویسندگان
چکیده
Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and allows the benefit of atrioventricular synchrony to be extended to a population with existing atrial fibrillation. Appropriate AMS depends on several parameters: a) the programmed parameters; b) the characteristics of the arrhythmia; c) the characteristics of the AMS algorithm. Three qualifying aspects constitute an AMS algorithm: onset, AMS response, and resynchronization. Since AMS programs also provide data on the time of onset and duration of AMS episodes, AMS data may be interpreted as a surrogate marker of ATAs recurrence. Recently, stored electrograms corresponding to episodes of ATAs have been introduced, thus clarifying the accuracy of AMS in detecting ATAs Clinically this information may be used to assess the efficacy of an antiarrhythmic intervention or the risk of thromboembolic events, and it may serve as a valuable research tool for evaluating the natural history and burden of ATAs.
منابع مشابه
Accuracy of mode switch algorithms for detection of atrial tachyarrhythmias.
INTRODUCTION In patients with permanent pacemakers, mode switching events often are interpreted as surrogate markers for atrial tachyarrhythmias. The aim of this study was to determine the accuracy of automatic mode switching algorithms in patients with permanent pacemakers for the diagnosis of atrial tachyarrhythmias. METHODS AND RESULTS Forty patients with tachycardia-bradycardia syndrome a...
متن کاملPacemaker repetitive nonreentrant ventriculoatrial synchrony. Why did automatic mode switching occur?
Repetitive nonreentrant ventriculoatrial synchrony during dual-chamber pacing is characterized by long intervals alternating with short intervals. This arrangement activated automatic mode switching in a St Jude dual-chamber pacemaker in which the algorithm requires an atrial sensed event for automatic mode switching initiation. Automatic mode switching activation by an atrial sensed event (ret...
متن کاملAtrioventricular nodal ablation and implantation of mode switching dual chamber pacemakers: effective treatment for drug refractory paroxysmal atrial fibrillation.
OBJECTIVE To assess the effect of atrioventricular node ablation and implantation of a dual chamber, mode switching pacemaker on quality of life, exercise capacity, and left ventricular systolic function in patients with drug refractory paroxysmal atrial fibrillation. PATIENTS 18 consecutive patients with drug refractory paroxysmal atrial fibrillation. METHODS Quality of life was assessed b...
متن کاملSwitch to DDD mode in SafeR algorithm could be delayed in paroxysmal atrial fibrillation and simultaneous occurrence of complete atrioventricular block.
Discussion SafeR pacing mode provides AAI pacing while continuously monitoring AV conduction. The device switches to DDD mode upon the occurrence of pause (2 or 3 s, in this case programmed in 2 s), or first-, secondor third-degree AV block. In our patient, none of these conditions was present during atrial pacing thus keeping in AAI. In this familyof pacemakers, the mode switch criterion due t...
متن کاملAssessment of P-wave indices as atrial fibrillation predictors in psoriasis patients
Background: Psoriasis is a prevalent chronic T cell mediated inflammatory skin disorder. Recent studies have reported an increase in the incidence of arrhythmia in psoriasis patients who run an excessive risk of metabolic syndrome and cardiovascular diseases. P-wave dispersion (PWD) and duration are important electrocardiographic (ECG) markers employed to anticipate the risk of atrial arrhythmi...