Quadratic Pulse Inversion Ultrasonic Imaging(QPI): A Two-Step Procedure for Optimization of Contrast Sensitivity and Specificity
نویسنده
چکیده
We have previously introduced an ultrasonic imaging approach that combines harmonic-sensitive pulse sequences with a post-beamforming quadratic kernel derived from a second-order Volterra filter (SOVF). This approach is designed to produce images with high sensitivity to nonlinear oscillations from microbubble ultrasound contrast agents (UCA) while maintaining high levels of noise rejection. In this paper, a two-step algorithm for computing the coefficients of the quadratic kernel leading to reduction of tissue component introduced by motion, maximizing the noise rejection and increases the specificity while optimizing the sensitivity to the UCA is presented. In the first step, quadratic kernels from individual singular modes of the PI data matrix are compared in terms of their ability of maximize the contrast to tissue ratio (CTR). In the second step, quadratic kernels resulting in the highest CTR values are convolved. The imaging results indicate that a signal processing approach to this clinical challenge is feasible. Keywords— Volterra Filter, Pulse Inversion, Ultrasonic Imaging, Contrast Agent.
منابع مشابه
Several microbubble ultrasound contrast agents (UCA) have been recently introduced to allow imaging blood perfusion in the mic
Several microbubble ultrasound contrast agents (UCA) have been recently introduced to allow imaging blood perfusion in the microvasculature. Microbubbles exhibit strong linear and nonlinear response to incident ultrasonic beams that can be utilized to increase the contrast-to-tissue ratio (CTR). If successful, this will lead to functional ultrasonic imaging methods. This increased interest in U...
متن کاملThe effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence
Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...
متن کاملدر ارزیابی سرطان سلول MRI و CT-Scan مقایسه (SCC) سنگفرشی حفره دهان
Background and purpose: Squamous Cell Carcinoma (SCC) is the most common head and neck malignancy. To decrease the side effects of treatment and the rate of mortality, careful staging for proper treatment plan is necessary. The purpose of this prospective study was to compare the diagnostic value of two different imaging methods (Computed Tomography (CT) and Magnetic Resonance Imaging (MRI)...
متن کاملOptimization of Bremsstrahlung imaging in Yttrium internal radiation therapy
Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کامل