Power measurement techniques for non-sinusoidal conditions The significance of harmonics for the measurement of power and other AC quantities
نویسنده
چکیده
The increased application of power electronics and other non-linear loads makes it necessary to re-evaluate the measuring techniques used in the power system, and the measuring problems these loads cause. An instrument utilising digital sampling techniques has been built and evaluated at the Swedish National Testing and Research Institute (SP). The Digital Sampling Watt Meter (DSWM) is based on standard laboratory equipment: digital multimeters, voltage dividers, shunt resistors and a PC. The DSWM is versatile and can be used for calibrations of many quantities. The most basic ones are the (total) active power and the amplitude and phase angle of individual harmonics of non-sinusoidal voltages and currents. The DSWM was first verified for sinusoidal signals. At 120 V and 5 A and power factor one, the DSWM has an estimated uncertainty (2σ) of 60 ppm at 50 Hz and 600 ppm at 20 kHz. The wattmeter has also participated in three international comparisons with satisfactory results. The most important additional feature, the input distortion, has been verified to be less than 800 ppm for all harmonics and lower than 100 ppm for most harmonics. Some AC quantities, as the reactive power, are not properly defined for nonsinusoidal situations. Efforts are made in this work to understand and explain the problems of extending the reactive power definition to cover nonsinusoidal conditions. The main conclusion is that reactive power is used to obtain information on more than one property of the power transmission mechanism, e. g. phase angle, transmission efficiency and line voltage drop. No single power definition can alone provide information on all these properties in a non-sinusoidal situation. Moreover, instrument designs may not comply with any of the extended definitions and these meters exhibit extra errors due to this non-compliance for non-sinusoidal conditions. Some conclusions on future demands on energy meters can be drawn, based on the error analysis of these meters and an analysis on how the responsibility for the harmonic currents and voltages in the power system can be determined and shared. One conclusion is that it is not possible to make a precise determination of the responsibility for harmonics based on any power measurement alone.
منابع مشابه
Modified Bi-directional AC/DC Power Converter with Power Factor Correction
Most existing power converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...
متن کاملA Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data
Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...
متن کاملA Non-Sinusoidal Reference Wave for Pwm Ac Drives
In this paper we propose a suitable reference wave for Pulse Width Modulation (PWM) AC Drives. Staircase reference waves whose levels are calculated to eliminate certain harmonics are studied and a certain staircase reference waveform with L levels is constructed. When L is made very large in limit, this staircase waveform approaches a continuous one which is called Quasine (Quasi + Sine). This...
متن کاملDesign and Implementation of a Kalman Filter-Based Time-Varying Harmonics Analyzer
Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...
متن کاملComparative Harmonic Loss Measurement of Grain Oriented and Non-oriented Magnetic Sheets Using a High Precision Single Sheet Tester
Abstract: Local flux may be distorted in many regions of core, although total flux is usually sinusoidal. When attempting to predict the loss distribution in materials operating under localized distorted flux conditions, which occur in machines and transformer cores, it is essential that proper account of the waveform be taken. Moreover for development of new magnetic materials and generation ...
متن کامل