Axillary and tympanic membrane temperature measurements are unreliable early after cardiopulmonary bypass.

نویسندگان

  • T A Khan
  • H A Vohra
  • S Paul
  • M D Rosin
  • R L Patel
چکیده

BACKGROUND AND OBJECTIVE Inaccurate measurements of body temperature following cardiopulmonary bypass may be associated with serious complications. The purpose of this study was to determine whether axillary and tympanic temperature measurements correlate with the urinary bladder temperature in the early postcardiac surgery period. METHODS Forty-nine adult patients who underwent cardiac surgery under cardiopulmonary bypass at our institution were prospectively studied. Urinary bladder, right axillary, right tympanic and left tympanic temperature measurements were simultaneously recorded at 0, 6, 12 and 18 h following cardiopulmonary bypass. Patients had one to four sets of recordings and a total of 629 temperature measurements were recorded. The mean difference (bias) between the bladder and each of the other methods and limits of agreement were calculated using Bland and Altman method. RESULTS The mean core body temperature recorded from the bladder on admission to the intensive care unit was 36.4 degrees C. After 6, 12 and 18 h the mean core body temperature was 37.4 degrees C (range: 35.2-39.0), 37.5 degrees C and 37.45 degrees C, respectively. The mean differences (bias) between the bladder temperature and the other three methods were: left tympanic, 0.65 degrees C (95% CI: -0.24 to 1.58); right tympanic, 0.57 degrees C (95% CI: -0.48 to 1.63) and right axillary, 0.55 degrees C (95% CI: -0.27 to 1.36). CONCLUSIONS The axilla and tympanic membrane are unreliable sites for core body temperature measurement early after cardiopulmonary bypass in adult patients and clinical decisions should be based on more reliable methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aural and Nasal Temperature Measurements Using an Infrared Thermometer vs Conventional Axillary and Oral Measurements

Introduction and Aim: The aim of the present study was to compare aural temperature measurements with conventional methods (axillary and oral) in patients with unilateral tympanic membrane perforation or myringosclerosis. The study also aimed to test the potential nasal use of infrared thermometer. Materials and Methods: Forty-four adult patients with monoaural tympanic membrane perforation and...

متن کامل

Do standard monitoring sites reflect true brain temperature when profound hypothermia is rapidly induced and reversed?

BACKGROUND Brain temperature is closely approximated by most body temperature measurements under normal anesthetic conditions. However, when thermal autoregulation is overridden, large temperature gradients may prevail. This study sought to determine which of the standard temperature monitoring sites best approximates brain temperature when deep hypothermia is rapidly induced and reversed durin...

متن کامل

[frontal, Axillary and Tympanic Temperature Measurements in Children].

The purpose of this study was to compare the results of body temperature measurements obtained by standard axillary thermometers with the results of infrared tympanic and frontal skin thermometry in afebrile children. This study comprises a single-center, prospective comparison trial. A total of 345 afebrile children aged 4 to 16 years hospitalized in the pediatric surgery department for electi...

متن کامل

An evaluation of tympanic thermometry in a paediatric emergency department.

BACKGROUND AND OBJECTIVES The consequences of missing fever in children can be grave. Body temperature is commonly recorded at the axilla but accuracy is a problem. This study aimed to evaluate the accuracy of a tympanic thermometer in the paediatric emergency setting. METHOD In a total of 106 infants, the body temperature was measured in the daytime with an infrared tympanic thermometer, and...

متن کامل

Comparison of Axillary and Tympanic Temperature Measurements in Children Diagnosed with Acute Otitis Media

Background. Acute otitis media [AOM] may affect the accuracy of tympanic temperature measurements. We aimed to compare tympanic temperature measurements in patients with AOM against control groups, as well as compare the tympanic temperatures with axillary thermometry. Methods. This is a prospective, observational study. Patients from pediatric outpatient and emergency clinics who were diagnose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of anaesthesiology

دوره 23 7  شماره 

صفحات  -

تاریخ انتشار 2006