High-resolution myocardial T1 mapping using single-shot inversion recovery fast low-angle shot MRI with radial undersampling and iterative reconstruction
نویسندگان
چکیده
OBJECTIVE To develop a novel method for rapid myocardial T1 mapping at high spatial resolution. METHODS The proposed strategy represents a single-shot inversion recovery experiment triggered to early diastole during a brief breath-hold. The measurement combines an adiabatic inversion pulse with a real-time readout by highly undersampled radial FLASH, iterative image reconstruction and T1 fitting with automatic deletion of systolic frames. The method was implemented on a 3-T MRI system using a graphics processing unit-equipped bypass computer for online application. Validations employed a T1 reference phantom including analyses at simulated heart rates from 40 to 100 beats per minute. In vivo applications involved myocardial T1 mapping in short-axis views of healthy young volunteers. RESULTS At 1-mm in-plane resolution and 6-mm section thickness, the inversion recovery measurement could be shortened to 3 s without compromising T1 quantitation. Phantom studies demonstrated T1 accuracy and high precision for values ranging from 300 to 1500 ms and up to a heart rate of 100 beats per minute. Similar results were obtained in vivo yielding septal T1 values of 1246 ± 24 ms (base), 1256 ± 33 ms (mid-ventricular) and 1288 ± 30 ms (apex), respectively (mean ± standard deviation, n = 6). CONCLUSION Diastolic myocardial T1 mapping with use of single-shot inversion recovery FLASH offers high spatial resolution, T1 accuracy and precision, and practical robustness and speed. Advances in knowledge: The proposed method will be beneficial for clinical applications relying on native and post-contrast T1 quantitation.
منابع مشابه
Real-time MRI at a resolution of 20 ms.
The desire to visualize noninvasively physiological processes at high temporal resolution has been a driving force for the development of MRI since its inception in 1973. In this article, we describe a unique method for real-time MRI that reduces image acquisition times to only 20 ms. Although approaching the ultimate limit of MRI technology, the method yields high image quality in terms of spa...
متن کاملMagnetic Resonance in Medicine 59:686–691 (2008) Radial Single-Shot STEAM MRI
Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a consequence, the achievable spatial resolution is limited when using conventiona...
متن کاملMyocardial T1 mapping at 3.0T using inversion recovery FLASH readout
Background Myocardial T1 mapping methods such as modified Look-Locker inversion-recovery (MOLLI) typically use balanced steady state free precession (bSSFP) readout, which is known to be particularly sensitive to off resonance and thus limits its utility at higher field strengths. Fast low angle shot (FLASH) imaging is known to be more robust against susceptibility artifacts than bSSFP. However...
متن کاملSimultaneous T1 mapping, cine imaging, and IR-prepared imaging of the rat heart using Small Animal Look-Locker Inversion recovery (SALLI)
Background: T1 mapping of the heart in rodents is challenging due to high heart rates, preventing the use of non-segmented MRI techniques that have been developed for human studies. We propose a novel acquisition and reconstruction scheme generating cardiac T1 maps, cine images and inversion recovery (IR)-prepared images at the same time. Methods: Small Animal Look-Locker Inversion recovery (SA...
متن کاملRadial single-shot STEAM MRI.
Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a consequence, the achievable spatial resolution is limited when using conventiona...
متن کامل