Diagnostic Accuracy of Five Serologic Tests for Strongyloides stercoralis Infection

نویسندگان

  • Zeno Bisoffi
  • Dora Buonfrate
  • Marco Sequi
  • Rojelio Mejia
  • Ruben O. Cimino
  • Alejandro J. Krolewiecki
  • Marco Albonico
  • Maria Gobbo
  • Stefania Bonafini
  • Andrea Angheben
  • Ana Requena-Mendez
  • José Muñoz
  • Thomas B. Nutman
چکیده

BACKGROUND The diagnosis of Strongyloides stercoralis (S. stercoralis) infection is hampered by the suboptimal sensitivity of fecal-based tests. Serological methods are believed to be more sensitive, although assessing their accuracy is difficult because of the lack of sensitivity of a fecal-based reference ("gold") standard. METHODS The sensitivity and specificity of 5 serologic tests for S. stercoralis (in-house IFAT, NIE-ELISA and NIE-LIPS and the commercially available Bordier-ELISA and IVD-ELISA) were assessed on 399 cryopreserved serum samples. Accuracy was measured using fecal results as the primary reference standard, but also using a composite reference standard (based on a combination of tests). RESULTS According to the latter standard, the most sensitive test was IFAT, with 94.6% sensitivity (91.2-96.9), followed by IVD-ELISA (92.3%, 87.7-96.9). The most specific test was NIE-LIPS, with specificity 99.6% (98.9-100), followed by IVD-ELISA (97.4%, 95.5-99.3). NIE-LIPS did not cross-react with any of the specimens from subjects with other parasitic infections. NIE-LIPS and the two commercial ELISAs approach 100% specificity at a cut off level that maintains ≥70% sensitivity. CONCLUSIONS NIE-LIPS is the most accurate serologic test for the diagnosis of S. stercoralis infection. IFAT and each of the ELISA tests are sufficiently accurate, above a given cut off, for diagnosis, prevalence studies and inclusion in clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Five Serologic Tests for the Follow up of Strongyloides stercoralis Infection

BACKGROUND Traditional faecal-based methods have poor sensitivity for the detection of S. stercoralis, therefore are inadequate for post-treatment evaluation of infected patients who should be carefully monitored to exclude the persistence of the infection. In a previous study, we demonstrated high accuracy of five serology tests for the screening and diagnosis of strongyloidiasis. Aim of this ...

متن کامل

Is the Baermann, an applicable method for detection of Strongyloides stercoralis?

Introduction: It is estimated that 100 - 300 million people in the world are infected with Strongyloides stercoralis. Although there are several laboratory diagnostic methods for detection of this parasite, there is still no gold standard diagnostic method. The need for an application test with high sensitivity and specificity is highly felt, especially in people with immune deficiency or organ...

متن کامل

Accuracy of molecular biology techniques for the diagnosis of Strongyloides stercoralis infection—A systematic review and meta-analysis

BACKGROUND Strongyloides stercoralis infection is a neglected tropical disease which can lead to severe symptoms and even death in immunosuppressed people. Unfortunately, its diagnosis is hampered by the lack of a gold standard, as the sensitivity of traditional parasitological tests (including microscopic examination of stool samples and coproculture) is low. Hence, alternative diagnostic meth...

متن کامل

شناسایی پروتئینهای لارو فیلاریفرم (L3) استرونژیلوئیدس استرکورالیس به روش وسترن بلات

Background: Strongyloides stercoralis is prevalent in tropical and subtropical regions of the world. S. stercoralis is the only nematodes with the ability to multiply in its host's body via autoinfection transmission. Larvae detection in faeces is difficult partly because of low egg production and irregular larvae excretion in faeces. Serologic tests (ELISA, IFA) are also diagnostic, however, S...

متن کامل

Diagnostic Accuracy of Kato–Katz, FLOTAC, Baermann, and PCR Methods for the Detection of Light-Intensity Hookworm and Strongyloides stercoralis Infections in Tanzania

Sensitive diagnostic tools are crucial for an accurate assessment of helminth infections in low-endemicity areas. We examined stool samples from Tanzanian individuals and compared the diagnostic accuracy of a real-time polymerase chain reaction (PCR) with the FLOTAC technique and the Kato-Katz method for hookworm and the Baermann method for Strongyloides stercoralis detection. Only FLOTAC had a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014