Improved Flutter Ablation Outcomes Using a 10mm-tip Ablation Catheter
نویسندگان
چکیده
INTRODUCTION Radiofrequency(RF) ablation has become the first line of therapy for atrial flutter(AFL). Advances in catheter and mapping technologies have led to better understanding and different approaches for treating this arrhythmia. We describe the results of different approaches to ablate this arrhythmia. MATERIALS AND METHODS A cohort of 198 patients with isthmus dependent AFL. The techniques used were: 10mm-tip catheter with power set to 100w, 8mm-tip catheter with power set to 60W and irrigated tip catheter. RESULTS 212 procedures, including redos were done in 198 consecutive patients. We used irrigated tip catheters in 14 procedures, 8mm-tip in 55 procedures, and 10mm-tip in 143 procedures. Bidirectional block was achieved in 97.6% of cases with all techniques, with no difference among them. Procedure time was shorter in the 10mm-tip versus 8mm-tip(69.6±30.6min vs.105±43min) or irrigated tip(180±90min) (P<0.05). Fluoroscopy time was also shorter in the 10mm-tip versus 8mm-tip (24±18min vs. 37±23min) or irrigated tip (110±25min)(P<0.05). The cumulative incidence of failure during follow-up was 1.2%/year in the 10mm, 10.1%year in the 8mm and 6.9%year in the irrigated tip. The survival free of a new procedure was significantly higher among 10mm patients. CONCLUSIONS In our series we found a high rate of acute success with the use of different techniques for AFL ablation. Procedure and fluoroscopic times were shorter with the use of 10mm-tip as compared with the others techniques. The long-term risk of recurrence was lower when we used the 10mm-tip catheter and the survival free of a second procedure was higher among patients treated with this catheter.
منابع مشابه
Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?
BACKGROUND The prospective, randomized study comparing 4- with 8-mm tip electrodes for radiofrequency linear ablation of typical atrial flutter is not available. METHODS AND RESULTS A total of 104 consecutive patients with typical atrial flutter were randomly assigned to undergo radiofrequency linear ablation using a 4- (Group I, n=54) or 8-mm tip electrode (Group II, n=50) catheter (temperat...
متن کاملProspective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter.
BACKGROUND Radiofrequency (RF) ablation of cavotricuspid isthmus (CTI) dependent flutter can be performed using different types of ablation catheters. It has been proposed that irrigated and large-tip catheters are capable of creating larger lesions, resulting in greater efficacy. This prospective, randomised clinical study compared the efficacy of irrigated and large-tip catheters of different...
متن کاملSuccessful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.
BACKGROUND Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS Of 170 patients referred for ablation of common atrial f...
متن کاملProspective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter.
BACKGROUND Radiofrequency (RF) ablation of common flutter requires the creation of a complete ablation line to produce bidirectional conduction block in the cavotricuspid isthmus. An irrigated-tip ablation catheter has been shown to be effective in patients in whom conventional ablation has failed. This randomized study compares the efficacy and safety of this catheter with those of a conventio...
متن کاملComparison of 8-mm-tip and irrigated-tip catheters in the ablation of isthmus-dependent atrial flutter: a prospective randomized trial.
INTRODUCTION AND OBJECTIVES Both 8-mm-tip and irrigated-tip catheters improve outcomes in typical atrial flutter ablation. However, it is not yet known which is preferable. The objective was to compare the effectiveness of 8-mm-tip (Group 1) and open irrigated-tip (Group 2) catheters in the first ablation attempt. METHODS A prospective randomized trial with a long-term follow-up was performed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -