Risk factors for intraaortic balloon pump use in coronary artery bypass surgery.
نویسندگان
چکیده
OBJECTIVES The study was aimed at investigating the risk factors of using an intraaortic balloon pump (IABP) in coronary artery bypass surgery and presenting the authors' clinical experience of IABP use. MATERIAL AND METHODS The study included 1094 patients who underwent coronary artery bypass surgery at the authors' clinic between January 2009 and December 2011. A comparison was made between 17 patients in whom an IABP was used and 1077 patients in whom it was not used. RESULTS An intraaortic balloon pump was used in 17 patients (1.55%) out of 1094 patients who underwent isolated coronary artery bypass surgery. The ratio of patients who had had preoperative myocardial infarction within the preceding 30 days, left main coronary artery stenosis of more than 50% and emergency surgery in Group 1 were higher than in Group 2 (p < 0.05). The total cardiopulmonary bypass time of Group 1 was found to be longer than that of Group 2 (p < 0.05). The demand for inotropics after weaning from cardiopulmonary bypass was greater in Group 1 than in Group 2 (p < 0.05). The need for reoperation (because of bleeding) was higher in Group 1 than in Group 2 (p < 0.05). The patients' stay on the intensive care unit was longer in Group 1 than in Group 2 (p < 0.05). Mortality rates were 29.4% in Group 1 and 1.2% in Group 2 (p < 0.05). CONCLUSIONS Preoperative myocardial infarction within the preceding 30 days, left main coronary artery stenosis of more than 50%, emergency surgery and long cardiopulmonary bypass time are important risk factors for IABP use in coronary artery bypass surgery.
منابع مشابه
On-Pump Beating Coronary Artery Bypass in High Risk Coronary Patients
Background: There are some conflicting results with Conventional Coronary Artery Bypass Grafts (CCABG) with arrested heart in coronary high-risk patients. Moreover, performing off-pump CABG in these cases may be associated with serious complications. The objective of this study is to evaluate the efficacy of the on-pump beating CABG (OPBCABG) in coronary high-risk patients in comparison with th...
متن کاملEvaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery
Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...
متن کاملInfluence of timing of intraaortic balloon placement in cardiac surgical patients.
OBJECTIVE The study objective was to evaluate the association between timing of intraaortic balloon pump insertion and outcomes in patients undergoing cardiac surgery. METHODS All patients aged 18 years or more who underwent coronary artery bypass surgery, cardiac valve surgery, or thoracic aortic surgery between January 2002 and December 2007 were included. Data were obtained from cardiac su...
متن کاملUse of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملPositioning an intraaortic balloon pump using intraoperative transesophageal echocardiogram guidance.
A 72-year-old man with an ejection fraction of 25% is scheduled to undergo elective coronary artery bypass graft using cardiopulmonary bypass. Because of the high-risk nature of the operation, the surgeon wants to insert an intraaortic balloon pump (IABP) before initiating cardiopulmonary bypass. An intraoperative transesophageal echocardiogram (TEE) is requested to ensure correct placement.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Advances in clinical and experimental medicine : official organ Wroclaw Medical University
دوره 23 2 شماره
صفحات -
تاریخ انتشار 2014