Time-gated optical system for depth-resolved functional brain imaging.
نویسندگان
چکیده
We present a time-domain optical system for functional imaging of the adult head. We first describe the instrument, which is based on a Ti:Sapphire pulsed laser (wavelength 750-850 nm) and an intensified CCD camera enabling parallel detection of multiple fibers. We characterize the system in terms of sensitivity and signal-to-noise ratio, instrument response function, cross-talk, stability, and reproducibility. We then describe two applications of the instrument: the characterization of baseline optical properties of homogeneous scattering media, and functional brain imaging. For the second application, we developed a two-part probe consisting in two squares of 4 x 4 sources and 3 x 3 detectors. The laser source is time-multiplexed to define 4 states of 8 sources that can be turned on during the same camera frame while minimizing cross-talk. On the detection side, we use for each detector 7 fibers of different lengths creating an optical delay, and enabling simultaneous detection in 7 windows (by steps of 500 ps) for each detector. This multiple window detection allows depth sensitivity. The imaging probe was tested on dynamic phantoms and a preliminary result on an adult performing a motor task shows discrimination between superficial and cortical responses to the stimulus on both hemispheres.
منابع مشابه
Quantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model
Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...
متن کاملMotivation for a coherence gated wavefront sensor (CG)-SH/WFS
Shack–Hartmann wavefront sensors (SH-WFS) have little sensitivity in depth and hence are unsuitable for microscopy and are limited for retinal imaging. We demonstrate the first direct Shack–Hartmann measurement of wavefront originating from a multiple-layer target, in the presence of significant stray reflections that render a standard SH-WFS inoperable. A coherence-gate SH-WFS is implemented b...
متن کاملOptical Imaging of the Motor Cortex in the Brain in Order to Determine the Direction of the Hand Movements Using Functional Near-Infrared Spectroscopy (fNIRS)
Introduction: In recent years, optical imaging has attracted a lot of attention from scholars as a non- aggressive, efficient method for evaluating the activities of the motor cortex in the brain. Functional near-infrared spectroscopy (fNIRS (is a tool showing the hemodynamic changes in a cortical area of the brain according to optical principles. The present study has been de...
متن کاملFunctional tomography using a time-gated ICCD camera
We present a system for near infrared functional tomography based on a single pulsed source and a time-gated camera, for non-contact collection over a large area. The mean penetration depth of diffusely reflected photons is dependent on the arrival time of photons, but not on the source-detector distance. Thus, time-encoded data can be used to recover depth information while photon exiting poin...
متن کاملLocalized near-infrared spectroscopy and functional optical imaging of brain activity.
Changes in cerebral blood flow (CBF) and cerebral metabolic rates (CMRO2) have been used as indices for changes in neuronal activity. Near-infrared spectroscopy (NIRS) can also measure cerebral haemodynamics and metabolic changes, enabling the possible use of multichannel recording of NIRS for functional optical imaging of human brain activity. Spatio-temporal variations of brain regions were d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 11 4 شماره
صفحات -
تاریخ انتشار 2006