Effect of patient support pads on image quality and dose in fluoroscopy.

نویسندگان

  • W R Geiser
  • W Huda
  • N A Gkanatsios
چکیده

An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating the patient (i.e., with-scatter geometry). Patient doses were expressed in terms of the total energy imparted to patients simulated by either a 10 cm (i.e., pediatric) or 20 cm (i.e., adult) acrylic phantoms. Changes in image quality were determined by measuring the relative visibility of circular disks in a Leeds Test Object 10 contrast-detail phantom. In the scatter-free geometry, the addition of 4 mm Al filtration reduced the energy imparted by 27% (10 cm phantom) and 20% (20 cm phantom). In the with-scatter geometry, the corresponding reductions in energy imparted were 17% and 9% for the 10 and 20 cm phantoms, respectively. The visibility of low contrast disks generally decreased as the thickness of the added aluminum increased but the location of the added Al (i.e., with-scatter or scatter-free geometry) had no significant effect on the resultant image quality. These results demonstrate that the use of patient support pads with a thickness of approximately 4 mm Al will generally have an adverse impact on fluoroscopic image quality and result in modest reductions (approximately 10%) of adult patient doses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Primary efforts to optimize image quality in chest direct digital radiography of pediatric patient (for the age group 0 to 1 and 1 to 5 years) with survey some effective parameters in image quality and patient dose

Introduction: This study, evaluate pediatric digital radiography. Due to the high rates of this test and the high sensitivity of children to ionizing radiation in comparison with adults, it is attempted to achieve near optimal conditions by reducing the dose and maintaining the image quality. The object of the study is to change the irradiation parameters such as kV and mA and ...

متن کامل

بررسی میزان کیفیت تصاویر رادیوگرافی در بیمارستان های ارجاعی دولتی شهرستان ساری در سال 96

Background and purpose: Image quality together with low patient dose is two important goals in radiography procedures. Acquire radiographic images with inadequate quality give rise to uselessly patient dose, improper diagnosis, waste the cost and impose the biological effect to the patients. In this study image quality was evaluated for most common radiographic procedures based on indentified i...

متن کامل

Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

BACKGROUND Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 1997