Radiation safety considerations for PET centers.

نویسندگان

  • T F Brown
  • N J Yasillo
چکیده

This article explains why technologists handling positron-emitting radionuclides may have higher measured radiation exposures than technologists working with single-photon emitting radionuclides. We will summarize measurements we have made, as well as those reported by other authors. In addition, we will describe the procedures implemented to minimize exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation safety issues with positron‐emission/computed tomography simulation for stereotactic body radiation therapy

Stereotactic body radiation therapy (SBRT) simulations using a Stereotactic Body Frame (SBF: Elekta, Stockholm, Sweden) were expanded to include 18F-deoxyglucosone positron-emission tomography (FDG PET) for treatment planning. Because of the length of time that staff members are in close proximity to the patient, concerns arose over the radiation safety issues associated with these simulations....

متن کامل

Dose Absorbed by Technologists in Positron Emission Tomography Procedures with FDG

The objective of this work was to evaluate radiation doses delivered to technologists engaged in different tasks involving positron emission tomography (PET) studies with FDG (fluorodeoxyglucose). This investigation was performed in two French nuclear medicine departments, which presented significant differences in their arrangements and radiation safety conditions. Both centers administered ab...

متن کامل

Assessment of Patient Absorbed Radiation Dose during Hysterosalpingography: A Pilot Study in Southwest Nigeria

Background: Hysterosalpingography (HSG) is an indispensable tool for diagnosing infertility in females. The procedure exposes female reproductive organs to ionizing radiation as the genitals are irradiated during the process. Investigating patient absorbed dose during the procedures is essential for effective radiological protection of the patient. Objective: This study aims to investigat...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

CONTINUING EDUCATION Radiation Safety Review for 511-keV Emitters in Nuclear Medicine

With the advent of high-energy collimators and dual-head coincidence cameras, standard nuclear medicine facilities will soon begin imaging with PET isotopes. The use of 511keV emitters raises new radiation safety concerns for technologists traditionally limited to handling mTc and other low-energy isotopes. This article is a basic review of positron emitters, measurement concerns, exposure rate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 1997