Stability Test of Ampicillin Sodium Solutions in the Accufuser® Elastomeric Infusion Device Using HPLC: UV Method

نویسندگان

  • Min-A. Kang
  • Ju-Seop Kang
چکیده

The stabilities of two kinds of solutions (30 mg/mL) of Ampicillin sodium in 0.9% NaCl in water (NS, normal saline) and in sterile water (SW) in the intravenous elastomeric infusion device (Accufuser) were evaluated based on recommended solutions and storage periods. The injectable NSand SW-Ampicillin solutions in the Accufuser device were stored and evaluated at controlled temperature (room temperature, 25 ̊C ± 2 ̊C and cold temperature, 4 ̊C ± 2 ̊C) during 7 days. Effects of the periods of storage (from 0 to 7 days) and the temperatures of storage (RT and CT) on the physicochemical appearances and concentrations of active compounds were determined. The visual clarity, pH, and concentrations of Ampicillin were determined by stability-indicating high-performance liquid chromatography (HPLC)-ultraviolet (UV) detection. The results showed that the amount of Ampicillin in studied solutions gradually decreased with time. The Ampicillin in NS, which was stored in CT, was relatively stable, retaining 94% of its original amount up to 7 days. The solution that showed least stability was Ampicillin in SW, which was stored in RT, retaining 80% of its original amount. Generally, solutions that were stored in CT were more stable than the solutions that were stored in RT. No significant changes in physical appearance or color of the solutions were observed during the study. Particles were not detected in any solution samples. In summary, two kinds of solutions of Ampicillin sodium, in NS and SW, showed different chemical stabilities with time in intravenous infusion device without any significant physical changes and retained about 94% vs 89% and 83% vs 80% of initial concentrations after 7 days in CT and RT, respectively. We suggest that 30 mg/mL of Ampicillin sodium in NS solution in an Accufuser infusion device which is stored in CT can be applicable for 7 days in clinical situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability of Nafcillin Sodium Solutions in the Accufuser® Elastomeric Infusion Device

The aim of this study was to investigate the stabilities of two kinds of solutions of nafcillin sodium (2.5 mg/mL) in 0.9% sodium chloride solution (NS, normal saline) and in injectable 5% dextrose water (D5W) in the intravenous elastomeric infusion device (Accufuser) based on recommended solutions and storage periods. The injectable nafcillin solutions (NSand D5W-nafcillin) in the Accufuser de...

متن کامل

Stability of commonly used antibiotic solutions in an elastomeric infusion device.

BACKGROUND The Accufuser silicone-based elastomeric infusion device has recently been approved for the Canadian market. OBJECTIVE To evaluate the stability of 5 antibiotics (cefazolin, ceftazidime, ceftriaxone, clindamycin, and vancomycin) in either 5% dextrose in water (D5W) or 0.9% sodium chloride in water (NS) after storage in Accufuser disposable silicone balloon infusers. METHODS The s...

متن کامل

Intravenous Suitability Studies of Commonly Used Oxacillin Sodium Solutions in the ACCUFUSER® Infusion Device

Our study compares two commonly used solutions of oxacillin sodium, 5.0 mg/mL in either 0.9% sodium chloride (NS) or 5% dextrose water (D5W), for their continued suitability for IV usage, and stability of active compound over time, when stored at two different controlled temperatures for six weeks. Both solutions were stored in an intravenous infusion device commercially available as Accufuser®...

متن کامل

Stability of Commonly Used Antibiotics Solutions in the Accufuser

Objectives: The stability of two kinds of solution of penicillin G potassium [PEN-K, 10K U/mL in 5% dextrose water, D5W and 50K U/mL in 0.9% sodium chloride in water, NS) into the intravenous infusion device, Accufuser ® , storage were evaluated at controlled temperature (CT, 4±2°C and RT, 25±2°C) during 6 weeks. Methods: Studies were performed using both NS (PEN-K 50K U/mL) and D5W (PEN-K 10K ...

متن کامل

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013