Liposomes loaded with contrast material for image enhancement in computed tomography. Work in progress.
نویسندگان
چکیده
Large unilamellar phospholipid vesicles were prepared and loaded with various radiographic contrast media. Body CT following in vivo administration of these vesicles in the rat demonstrated opacification of organs associated with the reticuloendothelial system. Image enhancement in the spleen and liver was dose dependent and was linearly related within the dose range investigated. Contrast enhancement was observed within five minutes of intravenous administration, was maximal 60 minutes after injection, and declined during the second hour. Clearance of the radiographic contrast material was complete within 24 hours. Diffuse splenic lymphoma following intraperitoneal or intrasplenic injection of lymphoma cells, and solitary lymphoma nodules following intrahepatic injection were readily detected as nonenhanced areas following injection of liposomes.
منابع مشابه
Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملNeuroimaging in Iran: A Review
ABSTRACTNeuroimaging allows noninvasive evaluation of the anatomy, physiology, and function of the brain. It is widely used for diagnosis, treatment planning, and treatment evaluation of neurological disorders as well as understanding functions of the brain in health and disease. Neuroimaging modalities include X-ray computed tomography (CT), magnetic resonance imaging (MRI), single photon emis...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملAssessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain
Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 152 3 شماره
صفحات -
تاریخ انتشار 1984