Enzyme immunoassay using a reusable extended-gate field-effect-transistor sensor with a ferrocenylalkanethiol-modified gold electrode.

نویسندگان

  • Masao Kamahori
  • Yu Ishige
  • Maki Shimoda
چکیده

A reusable extended-gate field-effect transistor (FET) sensor with an 11-ferrocenyl-1-undecanethiol (11-FUT) modified gold electrode was developed for applying to enzyme immunoassay. It was found that the 11-FUT modified FET sensor detected a thiol compound 50 times or more repeatedly after a treatment with a 5% hydrogen peroxide solution. The gate-voltage shift of the FET sensor showed a fairly good linearity (R(2) = 0.998) within a range from 10(-2) to 10(-6) M on the concentration of 6-hydroxyl-1-hexanethiol, which is a thiol compound, at a Nernstian response of 58.5 mV/decade. The FET-based immunoassay was constructed by combining the 11-FUT modified-FET sensor with the enzyme-linked immunosorbent assay (ELISA), in which the enzyme chemistry of acetylcholinesterase (AChE) was used to generate a thiol compound. The 11-FUT modified FET sensor with an AC voltage at 1 MHz superimposed onto the reference electrode detected the AChE-catalyzed product corresponding to a serum concentration of interleukin 1beta from 10 to 5000 pg/mL. In addition, all measurements were successfully performed by using the same FET-sensor chip after a treatment with a 5% hydrogen peroxide solution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extended-Gate Field-Effect Transistor based Sensor for Detection of Hyoscine N-Butyl Bromide in its Pharmaceutical Formulation

A novel recognition method for selective determination of the hyoscine N-Butyl bromide (HBB), an antispasmodic agent for smooth muscles, was devised using extended gate field-effect transistor (EG-FET) as transducing unit. For this purpose a PVC membrane, containing hyoscine n-butyl-tetraphenyl borate ion-pair as recognition component, was coated on Ag/AgCl wire, which was connected to the exte...

متن کامل

Highly specific and sensitive non-enzymatic determination of uric acid in serum and urine by extended gate field effect transistor sensors.

A potentiometric non-enzymatic sensor using off-chip extended-gate field effect transistor (EGFET) with a ferrocenyl-alkanethiol modified gold electrode is demonstrated for determining the uric acid concentration in human serum and urine. Hexacyanoferrate (II) and (III) ions are used as redox reagent. This potentiometric sensor measures the interface potential on the ferrocene immobilized gold ...

متن کامل

A mercury(II) ion sensor device based on an organic field effect transistor with an extended-gate modified by dipicolylamine.

Herein, we report an organic field effect transistor (OFET) with an extended-gate modified by an artificial receptor for the detection of mercury(II) ions (Hg(2+)) in water. The sensor device is easy to fabricate, reusable, disposable, and portable. Thus OFET sensors could be applied for low-cost on-site detection of Hg(2+).

متن کامل

DNA detection by an extended-gate FET sensor with a high-frequency voltage superimposed onto a reference electrode.

An extended-gate field-effect-transistor (FET) sensor with a gold-sensing electrode, to which a gold-thiol bond could easily be applied, was developed for DNA detection. Because the gold electrode is located in a different area from the FET, it can be operated without a light-shielding box by masking only the FET. However, when the FET sensor is used in an aqueous solution, fluctuation of the i...

متن کامل

Effect of Aspect Ratio (Length:Diameter) on a Single Polypyrrole Nanowire FET Device

The effect of different aspect ratios (length to diameter ratio, L:D) on single polypyrrole (Ppy) nanowire based field effect transistor (FET) sensors for real time pH monitoring was studied. Ppy nanowires with diameters of ∼60, ∼80, and ∼200 nm were synthesized by using electrochemical deposition inside anodized aluminum oxide (AAO) template and were assembled using AC dielectrophoretic alignm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 24 9  شماره 

صفحات  -

تاریخ انتشار 2008