Clinical evaluation of immunoinhibition determination of creatine kinase B subunits in coronary care.

نویسندگان

  • J Booth
  • P J McCarthy
  • R N Walmsley
چکیده

One hundred patients with chest pain of cardiac origin were evaluated on the basis of clinical findings, electrocardiograph results, and total creatine kinase (CK) and creatine kinase B-subunit (CK-B) activity (as determined by immunoinhibition with the Boehringer CK-MB kit) in serum. All patients diagnosed as having had an acute myocardial infarction had increased values for both CK-B and total CK. In no case was normal total CK activity associated with an increased CK-B, nor was normal CK-B associated with an increased total CK. During collection of data for reference ranges, we found 10 patients who had no evidence of cardiac disease but had various other diseases, who exhibited high values for CK-B in serum; four of these had normal values for total CK. We conclude that estimations of CK-B in serum by this method added no more diagnostic information than did data on total CK in the evaluation of chest pain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and clinical evaluation of a microcentrifugal analyzer method for determining creatine kinase MB isoenzyme.

We have adapted to a microcentrifugal analyzer an immunoinhibition assay for measuring the activity of creatine kinase MB by using an inhibitory antibody for the M monomer. The method actually measures half the MB activity, but results are not multiplied by two because atypical isoenzymes of creatine kinase, including BB, IgG-BB, and the isoenzyme derived from mitochondria, are also detected, i...

متن کامل

Clinical and analytical evaluation of kits for measurement of creatine kinase isoenzyme MB.

We studied the analytical and clinical performance of six methods for creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB): three immunoassays (Behring, Hybritech, and International Immunoassay Labs); one immunoinhibition assay (Roche); one immunoinhibition/column method (Du Pont); and one electrophoretic method (Beckman). Between-day precision for all kits was poor at the upper reference limit. A...

متن کامل

Creatine kinase isoenzyme MB determination on the ACA: dependence on serum matrix and other effectors.

Creatine kinase isoenzyme MB catalytic activities in human serum, determined by ACA ion exchange chromatography and immunoinhibition, differ significantly, the correlation coefficient being 0.88. The reasons for this variation are interference of antibodies with the creatine kinase B subunit in the immunoinhibition assay, nonreproducible elution of creatine kinase isoenzyme MB from the ion exch...

متن کامل

An immunoinhibition assay for determination of creatine kinase isoforms in serum.

We report a preliminary evaluation of an immunoinhibition assay for creatine kinase isoform quantification. The procedure employs the monoclonal antibody CKM-G01, which inhibits the native M subunit of creatine kinase. The antibody does not inhibit the M subunit modified by removal of lysine by plasma carboxypeptidase N. Residual activity after treatment with the antibody is therefore due to se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 1983