The Effects of Local Modes on Vibration Reduction of Building Isolation
نویسندگان
چکیده
This paper investigates the vibration isolation performance of isolated box structures. Isolated box inside building is a one of the building isolation designs. Some experimental methods are developed to analyze the effects of bending mode of the box structure on vibration isolation efficiency. The vibration reduction performance of an isolated box inside building is found to be degraded by bending resonances of the isolated box. In the design of building isolation, apart from the conventional design of natural frequency of rigid body vibration, the control of local mode resonance frequencies is found to be also important.
منابع مشابه
The Empirical Assessment of Vibration in HVAC Systems
Background and purpose: Vibration caused by ventilation systems in buildings is one of the harmful physical factors that can cause harm to residents. Therefore, measuring and controlling vibration is important. Materials and Methods: In the first step of the study, the vibration accelerometer was placed on the base of a fan where the vibrations were sent toward the duct wall. A vibration asse...
متن کاملکنترل فعال ارتعاشات موضعی یک ورق مستطیلی با وصلههای پیزوالکتریک
Active control vibrations of an arbitrary point of a simply supported rectangular plate is presented in this paper. The governing differential equation of plate with attached piezoelectric sensor/actuator patches, whose effects of mass and stiffness are included by the local functions, is solved at first. The response of the plate is computed using the first nine natural modes. Then, piezoelec...
متن کاملAttenuating vibration transmission from a Town Board Station (TBS) to the neighbor residential building using an optimum isolator: A case study
Town Board Stations (TBS) are usually located in residential areas. Pressure reduction through reducing valves in these stations generates considerable amounts of sound and vibrations. These mechanical...
متن کاملDeveloping a Feature Extraction of Existing Structures Using an Ambient Vibration Test
The paper aims to extract the dynamic properties of existing structures without utilizing the analytical models. The ambient vibration testing could be used on any type of frame such as concrete, steel and masonry to investigate the structural vulnerability. The method could be the first stage and necessarily for the retrofit process. To achieve this aim, the ambient vibration testing can...
متن کاملStudy and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems
In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...
متن کامل