Analysis and Validation of Contactless Time-Gated Interrogation Technique for Quartz Resonator Sensors
نویسندگان
چکیده
A technique for contactless electromagnetic interrogation of AT-cut quartz piezoelectric resonator sensors is proposed based on a primary coil electromagnetically air-coupled to a secondary coil connected to the electrodes of the resonator. The interrogation technique periodically switches between interleaved excitation and detection phases. During the excitation phase, the resonator is set into vibration by a driving voltage applied to the primary coil, whereas in the detection phase, the excitation signal is turned off and the transient decaying response of the resonator is sensed without contact by measuring the voltage induced back across the primary coil. This approach ensures that the readout frequency of the sensor signal is to a first order approximation independent of the interrogation distance between the primary and secondary coils. A detailed theoretical analysis of the interrogation principle based on a lumped-element equivalent circuit is presented. The analysis has been experimentally validated on a 4.432 MHz AT-cut quartz crystal resonator, demonstrating the accurate readout of the series resonant frequency and quality factor over an interrogation distance of up to 2 cm. As an application, the technique has been applied to the measurement of liquid microdroplets deposited on a 4.8 MHz AT-cut quartz crystal. More generally, the proposed technique can be exploited for the measurement of any physical or chemical quantities affecting the resonant response of quartz resonator sensors.
منابع مشابه
Design, Simulation And Testing Of Planar Spiral Coils For The Time-Gated Interrogation Of Quartz Resonator Sensors
A technique for contactless electromagnetic interrogation of quartz resonator sensors is proposed and validated. The technique is based on the separation in time of the excitation and detection phases, exploiting the sensing of the transient response of the resonator. Contactless operation is achieved by means of electromagnetic coupling between spiral planar coils connected to the interrogatio...
متن کاملContactless Interrogation System for Capacitive Sensors with Time-Gated Technique †
This paper presents a measurement technique and system for the contactless interrogation of capacitive sensors via electromagnetic coupling. The interrogation unit employs a primary coil to periodically excite the capacitive sensor connected to a secondary coil forming an LC resonant circuit. When the excitation to the primary coil is switched off the damped response of the LC circuit is detect...
متن کاملIsolated electrodeless high-frequency quartz crystal microbalance for immunosensors.
This paper presents a contactless technique to measure shear bulk wave resonance frequencies of an isolated quartz crystal in a flow cell. The line antenna placed outside the cell generates and detects the resonance frequencies in a wireless-electrodeless manner. It is revealed that this mechanism relies on the quasistatic electric field. A 0.3-mm-thick AT-cut quartz was used, and its overtone ...
متن کاملReview of Transducer Principles for Label-Free Biomolecular Interaction Analysis
Label-free biomolecular interaction analysis is an important technique to study the chemical binding between e.g., protein and protein or protein and small molecule in real-time. The parameters obtained with this technique, such as the affinity, are important for drug development. While the surface plasmon resonance (SPR) instruments are most widely used, new types of sensors are emerging. Thes...
متن کاملValidation of a Phase-Mass Characterization Concept and Interface for Acoustic Biosensors
Acoustic wave resonator techniques are widely used in in-liquid biochemical applications. The main challenges remaining are the improvement of sensitivity and limit of detection, as well as multianalysis capabilities and reliability. The sensitivity improvement issue has been addressed by increasing the sensor frequency, using different techniques such as high fundamental frequency quartz cryst...
متن کامل