Remote mid-infrared photoacoustic spectroscopy with a quantum cascade laser.

نویسندگان

  • Thomas Berer
  • Markus Brandstetter
  • Armin Hochreiner
  • Gregor Langer
  • Wolfgang Märzinger
  • Peter Burgholzer
  • Bernhard Lendl
چکیده

We demonstrate non-contact remote photoacoustic spectroscopy in the mid-infrared region. A room-temperature-operated pulsed external-cavity quantum cascade laser is used to excite photoacoustic waves within a semitransparent sample. The ultrasonic waves are detected remotely on the opposite side of the sample using a fiber-optic Mach-Zehnder interferometer, thereby avoiding problems associated with acoustic attenuation in air. We present the theoretical background of the proposed technique and demonstrate measurements on a thin polystyrene film. The obtained absorption spectrum in the region of 1030-1230  cm(-1) is compared to a spectrum obtained by attenuated total reflection, showing reasonable agreement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mid-infrared photoacoustic spectroscopy of solids using an external-cavity quantum-cascade laser.

We describe the use of a pulsed external-cavity quantum-cascade laser (EC-QCL) for the acquisition of mid-IR photoacoustic (PA) spectra of solids. The EC-QCL employed in this work operates from 990 to 1075 cm(-1) (9.30-10.10 microm). A gas-microphone PA cell was used as the detector, and the signal was demodulated using a lock-in amplifier. PA EC-QCL spectra of solids display bands significantl...

متن کامل

Dual beam photoacoustic infrared spectroscopy of solids using an external cavity quantum cascade laser.

Quantum cascade laser-based instrumentation for dual beam photoacoustic (PA) spectroscopy is described in this article. Experimental equipment includes a 4.55 μm (2141-2265 cm(-1)) continuous wave external cavity quantum cascade laser (EC-QCL), two gas-microphone PA cells, and two lock-in amplifiers. Correction for the time and wavenumber dependence of the laser output is effected through real-...

متن کامل

Quantum Cascade Laser-Based Photoacoustic Spectroscopy for Trace Vapor Detection and Molecular Discrimination

We report on the development of a microelectromechanical systems (MEMS)-scale photoacoustic sensor for the detection of trace gases. A mid-infrared quantum cascade laser (QCL) was used to determine detection limits for acetic acid, acetone, 1,4-dioxane, and vinyl acetate. The source was continuously tunable from 1015 cm(-1) to 1240 cm(-1), allowing for the collection of photoacoustic vibrationa...

متن کامل

Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics

Diabetes mellitus is a widespread metabolic disease without cure. Great efforts are being made to develop a non-invasive monitoring of the blood glucose level. Various attempts have been made, including a number of non-optical approaches as well as optical techniques involving visible, near- and mid-infrared light. However, no true breakthrough has been achieved so far, i.e., there is no fully ...

متن کامل

Recent Advances in Trace Gas Detection Using Quantum and Interband Cascade Lasers

There is an increasing need in many chemical sensing applications ranging from environmental science to industrial process control as well as medical diagnostics for fast, sensitive, and selective trace gas detection based on laser spectroscopy. The recent availability of novel pulsed and continuous wave (cw) quantum and interband cascade distributed feedback (QC and IC DFB) lasers as mid-infra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 40 15  شماره 

صفحات  -

تاریخ انتشار 2015