Partial volume correction for positron emission images using the wavelet transform

نویسندگان

  • Antonello E Spinelli
  • Carlo Bergamini
  • Romano Zannoli
  • Gianfranco Cicoria
  • Mario Marengo
  • Luca Guerrieri
  • Claudio Lamberti
چکیده

A method for partial volume correction of positron emission tomography (PET) images is proposed. The method is based on combining information from PET and high resolution anatomical images. Two different algorithms fast wavelet transform and à trous were implemented in order to decompose the PET and high resolution images. Results obtained using several simulated images show a significant partial volume reduction and image enhancement. The relative errors in the partial volume corrected image are always less than 3,6% with respect to 16% of the original image. Key–Words: Positron emission tomography, wavelet transform, partial volume correction

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Wavelet Transform for Noise Reduction in Simulated PET Images

Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

Wavelet-Based De-noising of Positron Emission Tomography Scans

A method to improve the Signal to Noise Ratio of Positron Emission Tomography scans is presented. A wavelet-based image decomposition technique decomposes an image into two parts, one which primarily contains the desired restored image and the other primarily the remaining unwanted portion of the image. Because the method is based on a texture extraction model that identifies the desired image ...

متن کامل

Performance Analysis Of Multi Source Fused Medical Images Using Multiresolution Transforms

Image fusion combines information from multiple images of the same scene to get a composite image that is more suitable for human visual perception or further image-processing tasks. In this paper the multi source medical images like MRI (Magnetic Resonance Imaging), CT (computed tomography) & PET (positron emission tomography) are fused using different multi scale transforms. We compare variou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006