A recirculation aerosol wind tunnel for evaluating aerosol samplers and measuring particle penetration through protective clothing materials.
نویسندگان
چکیده
A recirculation aerosol wind tunnel was designed to maintain a uniform airflow and stable aerosol size distribution for evaluating aerosol sampler performance and determining particle penetration through protective clothing materials. The oval-shaped wind tunnel was designed to be small enough to fit onto a lab bench, have optimized dimensions for uniformity in wind speed and particle size distributions, sufficient mixing for even distribution of particles, and minimum particle losses. Performance evaluation demonstrates a relatively high level of spatial uniformity, with a coefficient of variation of 1.5-6.2% for wind velocities between 0.4 and 2.8 m s(-1) and, in this range, 0.8-8.5% for particles between 50 and 450 nm. Aerosol concentration stabilized within the first 5-20 min with, approximately, a count median diameter of 135 nm and geometric standard deviation of 2.20. Negligible agglomerate growth and particle loss are suggested. The recirculation design appears to result in unique features as needed for our research.
منابع مشابه
Laboratory study of selected personal inhalable aerosol samplers.
Assessment of inhalable dust exposure requires reliable sampling methods in order to measure airborne inhalable particles' concentrations. Many inhalable aerosol samplers can be used but their performances widely vary and remain unknown in some cases. The sampling performance of inhalable samplers is strongly dependent on particle size and ambient air velocity. Five inhalable aerosol samplers h...
متن کاملStudy on Aerosol Penetration Through Clothing and Individual Protective Equipment
Aerosol particles can readily penetrate through air permeable fabrics. Air flow and aerosol deposition models were used to determine the skin deposition rates of aerosols through up to two fabric layers. These models were used in conjunction with a plume dispersion model to examine the risks associated with wearing air permeable CBR protective clothing, to inform IPE fabric development programs...
متن کاملPerformance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.
While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the...
متن کاملResearch Papers Involving the Tsi Respicontm Sampler
Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 mm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RESPICONTM sampler, a...
متن کاملEvaluation of six inhalable aerosol samplers.
Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 microm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RespiCon, an Inst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 55 7 شماره
صفحات -
تاریخ انتشار 2011