The Effect of the Light Intensity and Light Distances of LED and QTH Curing Devices on the Hardness of Two Light-Cured Nano-Resin Composites

نویسندگان

  • Pnina Segal
  • Diva Lugassy
  • Eitan Mijiritsky
  • Michal Dekel
  • Ariel Ben-Amar
  • Zeev Ormianer
  • Shlomo Matalon
چکیده

Background: Effective polymerization of the composite resin is essential to obtain long term clinical success and has a great importance obtaining improved mechanical properties. The purpose of this study was to measure the effect of the light intensity of LED and QTH curing devices in relation to the light distances, on the hardness (KHN) of two light cure nano-resin composite. Material and Methods: The top and bottom surfaces of the two nanofill composite specimens were evaluated. Two LED and two QTH light curing devices were used at nine different distances. Light intensity was measured with two radiometers placed at these same distances from the curing tip. 360 pvc dies were prepared with circular cavity 3 mm in diameter and 2 mm thick. The tested materials were placed in each cavity. The different light curing distances were standardized by adding pvc spacers dies at different height matching the different distances. Top and bottom surface microhardness were evaluated with a Micro Hardness Tester in knoop hardness numbers (Kg/mm2). Data were statistically analyzed using: Three-way ANOVA, Tukey and Pearsons test. Results: It was revealed that there was a statistically significant difference in microhardness between the composites (p < 0.001), between the nine distances (p < 0.001) and between the four light curing devices (p < 0.001). Increasing the distance of the light source from composite resin, the light intensity and the microhardness values at the top and bottom surface decrease. LED light curing devices produced a greater microhardness results at the bottom surface of the specimens. The Filtek Ultimate nanocomposite (3 m) showed highest microhardness values on the top and bottom surfaces, polymerized with all four curing devices and all nine distances compared to Empress Direct nano composite (Ivoclar vivadent). Clinical significant: Even with high power LED curing light, the distance between the tip of the light source and the restoration surface should be as close as possible. In this study, Filtek Ultimate showed better results (highest microhardness values) than Empress

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Color Stability of a Microhybrid Resin Composite Polymerized with LED and QTH Light Curing Units

Introduction: Discoloration of resin composites is a common reason for replacement of these restorations. The aim of this study was to eva-luate the influence of different light curing de-vices on color stability of a microhybrid resin composite. &nbsp;Materials and Methods: 80 disc-shaped speci-mens (8 mm in diameter, 2-mm height) were fabricated from filtek Z250 resin composite. Specimens wer...

متن کامل

A comparative study of the effects of QTH and LED light curing units on the surface hardness of colored compomer and Hybrid composites

Introduction: One factor affecting the degree of polymerization is the type of light-curing device. The aim of this study was to compare the effects of LED and QTH light curing units on the surface hardness of composite and compomer. Materials & Methods: In this experimental study, 30 samples of composite and compomer were divided into 3 groups of 10 each. One-half of the subgroups in each g...

متن کامل

Comparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT

Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specim...

متن کامل

Evaluation of a second-generation LED curing light.

BACKGROUND Light-emitting diode (LED) curing lights offer advantages over quartz-tungsten-halogen (QTH) lights, but the first-generation LED lights had some disadvantages. PURPOSE This study compared a second-generation LED light with a QTH light to determine which was better at photopolymerizing a variety of resin composites. METHODS The ability of a LED light used for 20 and 40 seconds to...

متن کامل

Hardness of composite resin polymerized with different light-curing units

Introduction: The degree of polymerization depends on the type of light-curing unit. The aim of this study was to compare the hardness of composite resin cured by LED and Halogen light curing units. Methods: In this experimental study, 20 cylindrical samples of Tetric Ceram composite were prepared. Half of them were cured with Ultralume 2 LED and the other half with Astralis 7 Halogen light ...