How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging.

نویسندگان

  • Jesper L R Andersson
  • Stefan Skare
  • John Ashburner
چکیده

Diffusion tensor imaging is often performed by acquiring a series of diffusion-weighted spin-echo echo-planar images with different direction diffusion gradients. A problem of echo-planar images is the geometrical distortions that obtain near junctions between tissues of differing magnetic susceptibility. This results in distorted diffusion-tensor maps. To resolve this we suggest acquiring two images for each diffusion gradient; one with bottom-up and one with top-down traversal of k-space in the phase-encode direction. This achieves the simultaneous goals of providing information on the underlying displacement field and intensity maps with adequate spatial sampling density even in distorted areas. The resulting DT maps exhibit considerably higher geometric fidelity, as assessed by comparison to an image volume acquired using a conventional 3D MR technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of K-Space Energy Spectrum Analysis for Inherent and Dynamic B0 Mapping and Distortion Correction in DTI

Introduction Diffusion tensor imaging (DTI) is a powerful technique for the noninvasive characterization of the microstructure of normal and pathological tissue. However, it is typically performed with echo-planar imaging (EPI) and is thus vulnerable to spatial and temporal variations of the static magnetic field (B0) caused by susceptibility effects near air/tissue interfaces, eddy currents in...

متن کامل

PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: application to high-resolution diffusion tensor imaging.

A technique integrating multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and parallel imaging is presented for diffusion echo-planar imaging (EPI) at high spatial resolution. The method combines the advantages of parallel imaging to achieve accelerated sampling along the phase-encoding direction, and PROPELLER acquisition to further decrease the...

متن کامل

Diffusion imaging in humans at 7T using readout-segmented EPI and GRAPPA.

Anatomical MRI studies at 7T have demonstrated the ability to provide high-quality images of human tissue in vivo. However, diffusion-weighted imaging at 7T is limited by the increased level of artifact associated with standard, single-shot, echo-planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce ...

متن کامل

Diffusion-weighted single-shot line scan imaging of the human brain.

Single-shot line scan imaging (LSI) was adapted to diffusion-weighted (DW) MRI by replacing the initial 90 degrees radiofrequency pulse of the underlying high-speed stimulated echo sequence by a DW spin-echo preparation period. Implementation on a 2. 0 T whole-body MRI system yielded DW images of the human brain with b factors of 750 s mm(-2) and total imaging times of about 500 ms either for a...

متن کامل

Turbo spin-echo diffusion-weighted MR of ischemic stroke.

PURPOSE Our objective was to determine whether a multisection technique, diffusion-weighted half-Fourier single-shot turbo spin-echo (HASTE) imaging, can compensate for the drawbacks common to other diffusion-weighted techniques; specifically, the need for echo-planar technology and the presence of susceptibility artifacts in areas close to the skull base. METHODS Forty subjects who were refe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 2003