Reduction of the potential for thermal damage during hip resurfacing.
نویسندگان
چکیده
Resurfacing arthroplasty of the hip is being used increasingly as an alternative to total hip replacement, especially for young active patients. There is concern about necrosis of the femoral head after resurfacing which can result in fracture and loosening. Most systems use a cemented femoral component, with the potential for thermal necrosis of the cancellous bone of the reamed femoral head. We used thermal probes to record temperatures close to the cement-bone interface during resurfacing arthroplasty. The maximum temperature recorded at the cement-bone interface in four cases was approximately 68 degrees C which was higher than that reported to kill osteocytes. A modified surgical technique using insertion of a suction cannula into the lesser trochanter, generous pulsed lavage and early reduction of the joint significantly reduced the maximum recorded cancellous bone temperature to approximately 36 degrees C in five cases (p = 0.014). We recommend the modified technique since it significantly reduces temperatures at the cement-bone interface.
منابع مشابه
Notching of the femoral neck during resurfacing arthroplasty of the hip: a vascular study.
During hip resurfacing arthroplasty, excessive valgus positioning or surgical technique can result in notching of the femoral neck. Although mechanical weakening and subsequent fracture of the femoral neck are well described, the potential damage to the retinacular vessels leading to an ischaemic event is relatively unknown. Using laser Doppler flowmetry, we measured the blood flow in 14 osteoa...
متن کاملMaximum temperatures of 89°C recorded during the mechanical preparation of 35 femoral heads for resurfacing
BACKGROUND AND PURPOSE We noticed that our instruments were often too hot to touch after preparing the femoral head for resurfacing, and questioned whether the heat generated could exceed temperatures known to cause osteonecrosis. PATIENTS AND METHODS Using an infra-red thermal imaging camera, we measured real-time femoral head temperatures during femoral head reaming in 35 patients undergoin...
متن کاملThe thermal effects of lavage on 57 ox femoral heads prepared for hip resurfacing arthroplasty
BACKGROUND AND PURPOSE Previously, we have documented surface temperatures recorded by thermography great enough to cause osteonecrosis of the femoral head during hip resurfacing. We now performed an in vitro investigation with 3 questions: (1) whether water irrigation reduced bone surface temperature, (2) whether external bone temperatures were similar to core temperatures, and (3) whether blu...
متن کاملHip ResuRfacing 2011
In 1938 Marion Smith-Peterson placed a cobalt chromium cup on a reshaped femoral head to perform the first hip resurfacing.15 Also, in 1938, Philip Wiles performed the first total hip replacement.17 Both procedures revolutionized the treatment of hip arthritis. Most surgeons are opposed to hip resurfacing because it is difficult to perform and there is a high rate of success with total hip repl...
متن کاملHip resurfacing increases bone strains associated with short-term femoral neck fracture.
Short-term femoral neck fracture is a primary complication associated with contemporary hip resurfacing. Some fractures are associated with neck notching, while others occur in the absence of notching. These unexplained fractures may be due to large magnitude strains near the implant rim, which could cause bone damage accumulation and eventual neck fracture. We used statistically augmented fini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 1 شماره
صفحات -
تاریخ انتشار 2007