Use of blood specimens collected on filter paper in screening for abnormal hemoglobins.

نویسندگان

  • R M Schmidt
  • E M Brosious
  • S Holland
  • J M Wright
  • G R Serjeant
چکیده

Both cellulose acetate electrophoresis and citrate agar electrophoresis were performed on 834 blood samples collected on filter paper in Jamaica and shipped for testing to the National Hemoglobinopathy Standardization Laboratory at the U.S. National Center for Disease Control. Additionally, 30 blood samples collected locally were stored on filter paper, in microhematocrit capillary tubes, and as whole blood specimens; at selected times the samples were tested for stability to determine the best sample-collection technique for hemoglobin electrophoresis. Results were most nearly accurate when both cellulose acetate electrophoresis and citrate agar testing were used. The methods are easy to perform, but results are unreliable if the blood samples on filter paper are stored at 4 degrees C for longer than two weeks before they are tested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Neonatal screening for hemoglobinopathies: a pilot study in Porto Alegre, Rio Grande do Sul, Brazil].

This study was conducted to establish the frequency of hemoglobinopathies among newborns undergoing screening tests for metabolic diseases at the University Hospital (Hospital de Clínicas) in Porto Alegre, Rio Grande do Sul, Brazil. Testing for abnormal hemoglobins was performed by isoelectric focusing electrophoresis on agarose gel with blood obtained by heel stick and applied to filter paper....

متن کامل

Cord blood screening for hemoglobin disorders by high-performance liquid chromatography.

Ion-exchange high-performance liquid chromatography was employed as a screening method for abnormal hemoglobins in the newborn period. Samples of cord blood collected in EDTA tubes were used for this analysis. Hemolysates were injected onto 4.1 X loo-mm Synchropak ion-exchange columns using an automatic injector. Hemoglobin separation was carried out by means of a sodium acetate gradient. A tot...

متن کامل

Detection of Alpha Thalasemia in Cord Blood in Bahawalpur Region

Background: Neonatal screening for abnormal hemoglobins provides a practical approach for the detection of sickling syndromes and other hemoglobin disorders such as a-thalassemia. Most screening programs utilize various electrophoretic techniques for the detection of abnormal hemoglobins Electrophoresis on cellulose acetate at pH 8.6 identifies increased amounts of Bart’s hemoglobin (Hb) associ...

متن کامل

f 3 - LipoproteinQuantitationin CordBloodSpottedon FilterPaper : A

We describe an electroimmunodiffusion technique for measuring /3-lipoprotein in cord blood spotted on filter paper. A series of cord-blood samples, taken from 916 consecutive live-birth infants, was spotted directly onto filter paper and assayed for /3-lipoprotein. Eleven had abovenormal /3-lipoprotein. Of these 11, seven were tested two to six months later, along with their parents, for total ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 1976