An In Vivo Rabbit Model for the Evaluation of Antimicrobial Peripherally Inserted Central Catheter to Reduce Microbial Migration and Colonization as Compared to an Uncoated PICC

نویسندگان

  • Nicholas D. Allan
  • Kamna Giare-Patel
  • Merle E. Olson
چکیده

Infection is the leading complication associated with intravascular devices, and these infections develop when a catheter becomes colonized by microorganisms. To combat this issue, medical device manufacturers seek to provide healthcare facilities with antimicrobial medical devices to prevent or reduce the colonization. In order to adequately evaluate these devices, an in vivo model is required to accurately assess the performance of the antimicrobial devices in a clinical setting. The model presented herein was designed to provide a simulation of the subcutaneous tunnel environment to evaluate the ability of an antimicrobial peripherally inserted central catheter (PICC), coated with chlorhexidine based technology, to reduce microbial migration and colonization compared to an uncoated PICC. Three samples of control, uncoated PICCs and three samples of coated PICCs were surgically tunneled into the backs of female New Zealand White rabbits. The insertion sites were then challenged with Staphylococcus aureus at the time of implantation. Animals were evaluated out to thirty days and sacrificed. Complete en bloc dissection and evaluation of the catheter and surrounding tissue demonstrated that the chlorhexidine coated catheter was able to significantly reduce microbial colonization and prevent microbial migration as compared to the standard, un-treated catheter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pericardial Effusion in an Extreme Low Birth Weight Neonate with Peripherally Inserted Central Catheter

Background: Pericardial effusion and cardiac tamponade are the rare complications of peripherally inserted central catheters (PICC insertion) in extreme low birth weight infants. In this regard, paying attention to these complications is of utmost importance, because they can result in infant death. Case report: The case of our infant is a sa...

متن کامل

An Unusual Peripherally Inserted Central Catheter (PICC) Fractured in Vivo with Embolization Happened in a Child: A Case Report

We report a case of a 7-year-old child who received a peripherally inserted central catheter (PICC) for chemotherapy. He suffered from an unusual PICC fracture in vivo with pulmonary embolism after eight circles of chemotherapeutic agents administered. In this case report, we review the literatures for the underlying pathophysiology of this uncommon phenomenon. IV nurses should consider the pos...

متن کامل

The establishment and evaluation of rabbit model for peripherally inserted central catheter.

PURPOSE To establish a model to simulate the clinical specific process of peripherally inserted central catheter (PICC) on rabbits, and detect how long the catheter can be indwelled. METHODS Seventeen healthy New Zealand white rabbits were inserted the PICC according to the clinical specific procedure. With the principle of random, the rabbits were divided into four groups (14d, 21d, 28d, 35d...

متن کامل

Upper extremity deep vein thrombosis after migration of peripherally inserted central catheter (PICC)

INTRODUCTION Peripherally inserted central venous catheters (PICC) are widely used in cancer patients and ultrasound-guided PICC insertion could improve success rate. The tip position of the catheter should be located at the border of lower one-third of the superior vena cava (SVC) and cavo-atrial junction. The migration is malposition at the late stage after PICCs were inserted, and catheter m...

متن کامل

بررسی ارتباط زمان ماندگاری کاتترهای وریدی محیطی در نوزادان و کودکان بستری با میزان بروز عوارض رگ‌گیری

Background & Aim: Peripherally intravenous catheters (PIVs) are an important part of therapy for hospitalized children. Although such catheters provide necessary vascular access, their use puts patients at risk for local and systemic infectious complications with serious morbidity. Migration of skin organisms at the insertion site into the coetaneous catheter tract with colonization of the cath...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012