Novel nanostructured biomaterials: implications for coronary stent thrombosis

نویسندگان

  • Varvara Karagkiozaki
  • Panagiotis G Karagiannidis
  • Nikolaos Kalfagiannis
  • Paraskevi Kavatzikidou
  • Panagiotis Patsalas
  • Despoina Georgiou
  • Stergios Logothetidis
چکیده

BACKGROUND Nanomedicine has the potential to revolutionize medicine and help clinicians to treat cardiovascular disease through the improvement of stents. Advanced nanomaterials and tools for monitoring cell-material interactions will aid in inhibiting stent thrombosis. Although titanium boron nitride (TiBN), titanium diboride, and carbon nanotube (CNT) thin films are emerging materials in the biomaterial field, the effect of their surface properties on platelet adhesion is relatively unexplored. OBJECTIVE AND METHODS In this study, novel nanomaterials made of amorphous carbon, CNTs, titanium diboride, and TiBN were grown by vacuum deposition techniques to assess their role as potential stent coatings. Platelet response towards the nanostructured surfaces of the samples was analyzed in line with their physicochemical properties. As the stent skeleton is formed mainly of stainless steel, this material was used as reference material. Platelet adhesion studies were carried out by atomic force microscopy and scanning electron microscopy observations. A cell viability study was performed to assess the cytocompatibility of all thin film groups for 24 hours with a standard immortalized cell line. RESULTS The nanotopographic features of material surface, stoichiometry, and wetting properties were found to be significant factors in dictating platelet behavior and cell viability. The TiBN films with higher nitrogen contents were less thrombogenic compared with the biased carbon films and control. The carbon hybridization in carbon films and hydrophilicity, which were strongly dependent on the deposition process and its parameters, affected the thrombogenicity potential. The hydrophobic CNT materials with high nanoroughness exhibited less hemocompatibility in comparison with the other classes of materials. All the thin film groups exhibited good cytocompatibility, with the surface roughness and surface free energy influencing the viability of cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

انفارکتوس راجعه میوکارد به دنبال ترومبوز بسیار دیررس در stent، گزارش یک مورد

Stent thrombosis as a complication of percutaneous coronary intervention frequently is associated with deadly events such as myocardial infarction and sudden death. Definitions of stent thrombosis have not been in a uniform manner in different clinical studies. Two episodes of acute ST elevation myocardial infarction nearly two years after implanting a drug – eluting stent in a 58-year-...

متن کامل

The need for stent-lesion matching to optimize outcomes of intracoronary stent implantation.

Intracoronary stents have markedly improved the outcomes of catheter-based coronary interventions. Intracoronary stent implantation rates of over 90% during coronary angioplasty are common. Stent implantations are associated with a small but statistically significant number of adverse outcomes including restenosis, thrombosis, strut malapposition, incomplete strut endothelialization, and variou...

متن کامل

Coronary Endothelial Dysfunction after Drug-Eluting Stent Implantation

Problem statement: Stent thrombosis, which may occur even one year after stent implantation, is a drawback of Drug-Eluting Stents (DES). Among the variety of causes of stent thrombosis after DES implantation, coronary endothelial dysfunction manifested or exaggerated by DES implantation should not be overlooked. This review article summarizes previous reports on coronary endothelial dysfunction...

متن کامل

Diabetes mellitus: a prothrombotic state Implications for outcomes after coronary revascularization

Coronary stent thrombosis is a serious problem in the drug-eluting stent era. Despite aggressive antiplatelet therapy during and after percutaneous coronary intervention (PCI), the incidence of sub-acute stent thrombosis remains approximately 0.5%-2%, which may represent a catastrophic clinical situation. Both procedural factors and discontinuation of antiplatelet therapy are normally associate...

متن کامل

Thrombosis of sirolimus-eluting coronary stent in the postanesthesia care unit.

A 44-yr-old woman with a drug-eluting coronary stent placement two weeks before surgery suffered a myocardial infarction in the postanesthesia care unit immediately after hysterectomy. She had missed only one dose of aspirin and clopidogrel preoperatively. Early recognition of subacute stent thrombosis and urgent percutaneous coronary intervention probably prevented her death. In this case repo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012