Detection of lipid core coronary plaques in autopsy specimens with a novel catheter-based near-infrared spectroscopy system.
نویسندگان
چکیده
OBJECTIVES This study sought to assess agreement between an intravascular near-infrared spectroscopy (NIRS) system and histology in coronary autopsy specimens. BACKGROUND Lipid core plaques cannot be detected by conventional tests, yet are suspected to be the cause of most acute coronary syndromes. Near-infrared spectroscopy is widely used to determine the chemical content of substances. A NIRS system has been developed and used successfully in 99 patients. METHODS Scanning NIRS was performed through blood in 212 coronary segments from 84 autopsy hearts. One histologic section was analyzed for every 2 mm of artery. Lipid core plaque of interest (LCP) was defined as a lipid core >60 degrees in circumferential extent, >200-microm thick, with a mean fibrous cap thickness <450 microm. The first 33 hearts were used to develop the algorithm; the subsequent 51 validation hearts were used in a prospective, double-blind manner to evaluate the accuracy of NIRS in detecting LCP. A NIRS-derived lipid core burden index for an entire artery was also validated by comparison to histologic findings. RESULTS The LCPs were present in 115 of 2,649 (4.3%) sections from the 51 validation hearts. The algorithm prospectively identified LCP with a receiver-operator characteristic area of 0.80 (95% confidence interval [CI]: 0.76 to 0.85). The lipid core burden index detected the presence or absence of any fibroatheroma with an area under the curve of 0.86 (95% CI: 0.81 to 0.91). A retrospective analysis of lipid core burden index conducted in extreme artery segments with either no or extensive fibroatheroma yielded an area under the curve of 0.96 (95% CI: 0.92 to 1.00), confirming the accuracy of spectroscopy in identifying plaques with markedly different lipid content under ideal circumstances. CONCLUSIONS This novel catheter-based NIRS system accurately identified lipid core plaques through blood in a prospective study in coronary autopsy specimens. It is expected that this novel capability will be of assistance in the management of patients with coronary artery disease.
منابع مشابه
In vivo validation of a catheter-based near-infrared spectroscopy system for detection of lipid core coronary plaques: initial results of the SPECTACL study.
OBJECTIVES To determine whether catheter-based near-infrared spectroscopy (NIRS) signals obtained with a novel catheter-based system from coronaries of patients are similar to those from autopsy specimens and to assess initial safety of NIRS device. BACKGROUND An intravascular NIRS system for detection of lipid core-containing plaques (LCP) has been validated in human coronary autopsy specime...
متن کاملNon-invasive cardiac imaging to unmask a very uncommon aetiology of an embolic stroke.
References 11–71 can be found in Supplementary data online. 1. Goldstein JA. Angiographic plaque complexity: the tip of the unstable plaque iceberg. J Am Coll Cardiol 2002;39:1464–7. 2. Moreno PR, Muller JE. Identification of high-risk atherosclerotic plaques: a survey of spectroscopic methods. Curr Opin Cardiol 2002;17:638–47. 3. Jaffer FA, Verjans JW. Molecular imaging of atherosclerosis: cli...
متن کاملDetection of lipid pool, thin fibrous cap, and inflammatory cells in human aortic atherosclerotic plaques by near-infrared spectroscopy.
BACKGROUND A method is needed to identify nonstenotic, lipid-rich coronary plaques that are likely to cause acute coronary events. Near-infrared (NIR) spectroscopy can provide information on the chemical composition of tissue. We tested the hypothesis that NIR spectroscopy can identify plaque composition and features associated with plaque vulnerability in human aortic atherosclerotic plaques o...
متن کاملDetection by intracoronary near-infrared spectroscopy of lipid core plaque at culprit sites in survivors of cardiac arrest.
With an estimated 300,000 cases occurring per year in the United States alone, sudden cardiac death remains a major public health problem and in many cases is the first manifestation of coronary artery disease. Autopsy studies have established that the causative event in many cases of sudden death is rupture of an intracoronary lipid core plaque with subsequent thrombus formation. Until recentl...
متن کاملIntracoronary Near-Infrared Spectroscopy (NIRS) Imaging for Detection of Lipid Content of Coronary Plaques: Current Experience and Future Perspectives
Acute coronary syndromes are frequently caused by "vulnerable" coronary plaques with a lipid-rich core. In 1993 near-infrared spectroscopy (NIRS) was first used to detect the lipid (cholesterol) content of atherosclerotic plaques in an experimental animal study. NIRS was then carefully validated using human atherosclerotic plaques (ex vivo), and has subsequently been developed for intracoronary...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 1 5 شماره
صفحات -
تاریخ انتشار 2008