Construction and Evaluation of a Fast Switching Trigger Circuit for a Cosmic Ray Detection Spark Chamber

ثبت نشده
چکیده

A pulsing circuit is designed and constructed capable of raising up to +6.7kV between plates of a small (~50cm side length) spark chamber. The device is triggered by the ~2V output of a cosmic ray detection device, and its overall gain of ~1:3000 is achieved by a sequence of amplifiers and fast switching devices – namely a Bipolar Junction Transistor (BJT), Insulated Gate Bipolar Transistor (IGBT), 1:53 gain pulsed transformer and a triggered spark gap. The qualitative response of each component is assessed with respect to its response and relaxation time. The overall delay time between electronic input and this 6.7kV pulse is found to be as short as 580±100ns. The response of the electronics is investigated under a range of square input pulse amplitudes and durations, simulating input pulses expected from the cosmic ray detector. A pulse shape of 200ns and depth of 2V or more is found to minimise rise times within limits set by adjacent components. The majority (over 60%) of the overall rise time is identified with the LC charging of the step-up transformer. The 55.7±2ms RC recharge time of the capacitor driving the transformer input limits the system’s maximum repetition rate to ~10Hz. It is found that the assembled system is compatible with operation of a small spark chamber, and recommendations are made regarding further fine tuning and potential future challenges.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Study of Breakdown Voltages for Triggered Spark Gap Switches

This study explains the breakdown mechanism in different triggered spark gap switches. Two different trigger electrode configurations are tested for the switch predischarge operation in a nitrogen laser circuit. The behavior of the breakdown voltage, when a trigger pulse is applied to the trigger electrode, is investigated, and the results are reported. Based on the experimental measurements ne...

متن کامل

Fast Trigger Generator for High Coulomb Spark Gap Switching Synchronisation

Design and implementation of a 10kV subnanosecond pulse generator using Trigatron type spark gap as a switch. Straightforward and compact trigger generator using pulse shaping network which produces a trigger pulse of subnanosecond rise time. A pulse power system requires delivering a high voltage, high coulomb in short rise time. This is achieved by using pulse shaping network comprises of par...

متن کامل

Fast UV detection by Cu-doped ZnO nanorod arrays chemically deposited on PET substrate

Well-aligned Cu-doped ZnO nanorods were successfully synthesized on polyethylene terephthalate (PET) substrate using chemical bath deposition method. The structural and optical properties of Cu-doped ZnO nanorods were investigated using X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), energy dispersive X-ray spectroscopy (EDX) and photoluminescence (PL) spectroscopy...

متن کامل

Possible EGRET Gamma-Ray Burst Detection Independent of BATSE Triggering

EGRET spark chamber data collected between 1991 April 22 and 1994 August 29 have been analyzed for gamma-ray burst events independent of BATSE triggering. To date, ve gamma-ray bursts that are coincident with a trigger from the BATSE instrument have been detected in the EGRET spark chamber. The EGRET-detected bursts have high energy power law tails and, in some cases, long duration emission. Be...

متن کامل

Improved Knock Detection Method Based on New Time-Frequency Analysis In Spark Ignition Turbocharged Engine

Premature combustion that affects outputs, thermal efficiencies and lifetimes of internal combustion engine is called “knock effect”. However knock signal detection based on acoustic sensor is a challenging task due to existing of noise in the same frequency spectrum. Experimental results revealed that vibration signals, generated from knock, has certain frequencies related to vibration resonan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014