Effect of benzalkonium chloride on the stability of the precorneal tear film in rabbit and man.
نویسندگان
چکیده
Benzalkonium chloride, a surface-active preservative commonly used in eyedrop preparations, has been shown to hasten the drying of the precorneal tear film. In the rabbit, 0.01 per cent benzalkonium (the concentration usually employed as a preservative) shortened the time required for the appearance of dry spots on the corneal surface by a factor of about four. In man, an approximately twofold hastening was demonstrated. This effect is thought to preclude the use of this substance as a preservative in eyedrop preparations for use as local anaesthetics.
منابع مشابه
A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.
PURPOSE To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination...
متن کاملEffect of Benzalkonium Chloride on Biofilm of Bacteria Causing Nosocomial Infectionstions
ABSTRACT Background and Objective: Biofilms are community of bacteria that attach to inanimate surfaces or living tissues via production of extracellular polymers and exopolysaccharide matrix. Microbial biofilms on various surfaces of the hospital environment are considered as a reservoir of infection spread. The present study aimed to evalu...
متن کاملEffect of water-in-oil microemulsions and lamellar liquid crystalline systems on the precorneal tear film of albino New Zealand rabbits
The aim of this study is to investigate the effect of phase transition water-in-oil (w/o) microemulsions (ME) and liquid crystalline systems (LC) on the precorneal tear film (PCTF). The study used six albino NZ rabbits and monitored the integrity and stability of the PCTF before and after instillation of test formulations. The effects were evaluated by assessment of the PCTF lipid layer using i...
متن کاملEvaporation rate of water from the precorneal tear film and cornea in the rabbit.
A technique for the study of evaporation from the precorneal and cornea! surfaces has been developed. Evaporation from the superficial lipid layer (SLL) has been measured to be 10.1 x 10~ Gm.cm.^secr When this lipid layer is removed, evaporation increases around fourfold. Evaporation from the dry epithelial surface occurs at a rate of 1.8 x JO" Gm.cmr^secr After the epithelium is removed, a twe...
متن کاملPrecorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.
PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 59 11 شماره
صفحات -