Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640.
نویسنده
چکیده
BACKGROUND Diabetes mellitus is an important diagnosis. New criteria have been defined for impaired glucose metabolism and, accordingly, there is a need for precise and accurate glucose analysis for the correct classification of patients. However, neither the World Health Organisation nor the National Service Framework for Diabetes in England and Wales deal with the associated analytical issues for plasma glucose. AIMS/METHODS To compare two different methods for plasma glucose with respect to European and CLIA '88 quality requirements. RESULTS Using several different graphical and statistical techniques, the YSI 2300 STAT was found to be 8.1-8.4% negatively biased for plasma glucose when compared with the Olympus AU640 method. CONCLUSIONS Such a large bias would have a large impact on the detection of diabetes mellitus in clinical practice and therefore this method should not be used to make a definitive diagnosis. The bias probably results from the fact that the YSI 2300 STAT uses an aqueous based standard.
منابع مشابه
Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial.
BACKGROUND This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. METHODS Up to three capillary blood samples (N = 393) were collected from 146 subjects with and without diabetes. One sample per subject wa...
متن کاملMultivariable adaptive closed-loop control of an artificial pancreas without meal and activity announcement.
BACKGROUND Accurate closed-loop control is essential for developing artificial pancreas (AP) systems that adjust insulin infusion rates from insulin pumps. Glucose concentration information from continuous glucose monitoring (CGM) systems is the most important information for the control system. Additional physiological measurements can provide valuable information that can enhance the accuracy...
متن کاملPlasma glucose measurement with the Yellow Springs Glucose Analyzer.
The Yellow Springs Glucose Analyzer, a device for the quantitative measurement of glucose concentrations, involves the use of immobilized glucose oxidase, incorporated on a membrane covering a hydrogen peroxide sensor. Operation of the instrument is simple. After an initial calibration, 25 microliter of plasma is injected into a reaction chamber. At 45 s a digital result for glucose is displaye...
متن کاملImproving lactate analysis with the YSI 2300 GL: hemolyzing blood samples makes results comparable with those for deproteinized whole blood.
To obviate the well-documented problem of hematocrit dependency of the Yellow Springs Instruments (YSI) whole-blood lactate analyzer, we modified the dilution buffer by including a lysing reagent. This makes the results comparable with those of methods performed with deproteinized whole-blood samples. No centrifugation step is needed, thus preserving the convenience of the YSI instrument for st...
متن کاملClinical evaluation of bionime rightest GM310 biosensors with a simplified electrode fabrication for alternative-site blood glucose tests.
BACKGROUND Most processes for fabricating biosensors applied to screen-printed carbon electrodes (SPCEs) are complex. This study presents a novel one-step process for manufacturing electrodes for injection-molding biosensors. METHODS During the sensor-fabrication process, barrel-plated gold electrodes were inserted into an injection-molded base. The electrode directly touched the electrical c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 57 7 شماره
صفحات -
تاریخ انتشار 2004