Porous carbon composite/enzyme glucose microsensor.

نویسندگان

  • C M Li
  • C S Cha
چکیده

An enzyme glucose microsensor using a glucose oxidase-immobilized porous carbon/Teflon composite microelectrode was developed. The microsensor was fabricated by etching a platinum microelectrode (platinum, radius of 25 and 50 micrometers) in hot aqua regia to create a cavity at the tip and then packing a porous carbon/Teflon composite, which was made from acetylene black and Teflon emulsion, into the cavity. Nafion was impregnated into the inner surface of porous carbon/Teflon composite electrode following immobilization of Os(bpy)3+2/+3 as electron transfer mediators. The loading amount of Os(bpy)3+2/+3 in the Nafion/porous carbon/Teflon composite electrode was found to be 7.0x10(-8) mole cm(-2), which is much higher than that in polymer modified electrodes reported in literatures. The microsensor was further dipped overnight in buffer solution containing glucose oxidase for enzyme modification. With both glucose oxidase and mediators in the porous carbon/Teflon composite surface, the sensor performance was evaluated in buffer solutions containing different glucose concentrations and serum samples for glucose determination. The microsensor showed directly electrochemical glucose oxidation on the Os(bpy)3+2/+3 impregnated enzyme/porous carbon/Teflon composite surface with linear response over concentration range of 0-15 mM and Machaelis behavior. Reliability and reproducibility were conducted in serum samples and glucose buffer solution, and the results demonstrated there was no significant decrease of amperometric response in air-saturated solution for one month. The sensor demonstrated potential in clinical diagnostic applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immobilization of glucose oxidase on chitosan-based porous composite membranes and their potential use in biosensors.

The glucose oxidase (GOx) enzyme was immobilized on chitosan-based porous composite membranes using a covalent bond between GOx and the chitosan membrane. The chitosan-based porous membranes were prepared by the combination of the evaporation- and non-solvent-induced phase separation methods. To increase the membrane conductivity, carbon nanotubes (CNTs) were added to the chitosan solution. The...

متن کامل

Template-free synthesis of porous graphitic carbon nitride/carbon composite spheres for electrocatalytic oxygen reduction reaction.

Porous graphitic carbon nitride/carbon composite spheres were synthesized using melamine and cyanuric acid, and glucose as the carbon nitride and carbon precursor, respectively. The 3D hierarchical composites efficiently catalyzed the oxygen reduction reaction with an onset potential of 0.90 V and a kinetic current density of 23.92 mA cm(-2). These merit their promising applications in fuel cel...

متن کامل

Sugar-based micro/mesoporous hypercross-linked polymers with in situ embedded silver nanoparticles for catalytic reduction

Porous hypercross-linked polymers based on perbenzylated monosugars (SugPOP-1-3) have been synthesized by Friedel-Crafts reaction using formaldehyde dimethyl acetal as an external cross-linker. Three perbenzylated monosugars with similar chemical structure were used as monomers in order to tune the porosity. These obtained polymers exhibit microporous and mesoporous features. The highest Brunau...

متن کامل

Immobilization of Glucose oxidase on Meso-porous Glass-ceramic with the Skeleton of CaTi4(PO¬4)6

Microporous glass ceramic with skeleton of CaTi4(PO¬4)6 with average pore size of 12.7 nm has been synthesized and used as a carrier of glucose oxidase. The glass ceramic was prepared by controlled heat treatment of glass samples, which causes the phase separation in their structure and creates CaTi4(PO¬4)6 and β-Ca3(PO4)2 phases. The β-Ca3(PO4)2 phase was dissolved by soaking the glass ceramic...

متن کامل

PVDF-Nafion nanomembranes coated microneedles for in vivo transcutaneous implantable glucose sensing.

We demonstrate that microporous PVDF membranes sandwiched between multiple layers of nanomaterials can be used for continuous monitoring of glucose level in vivo. This is achieved by coating needle electrodes with Polyaniline nanofiber, Platinum nanoparticles, glucose oxidase enzyme and porous layers, successfully fabricated with layer-by-layer deposition. Nanoparticles incorporated into conduc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Frontiers in bioscience : a journal and virtual library

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2004