Influence of internal fixation systems on radiation therapy for spinal tumor

نویسندگان

  • Jingfeng Li
  • Lei Yan
  • Jianping Wang
  • Lin Cai
  • Dongcai Hu
چکیده

In this study, the influence of internal fixation systems on radiation therapy for spinal tumor was investigated in order to derive a theoretical basis for adjustment of radiation dose for patients with spinal tumor and internal fixation. Based on a common method of internal fixation after resection of spinal tumor, different models of spinal internal fixation were constructed using the lumbar vertebra of fresh domestic pigs and titanium alloy as the internal fixation system. Variations in radiation dose in the vertebral body and partial spinal cord in different types of internal fixation were studied under the same radiation condition (6 MV and 600 mGy) in different fixation models and compared with those irradiated based on the treatment planning system (TPS). Our results showed that spinal internal fixation materials have great impact on the radiation dose absorbed by spinal tumors. Under the same radiation condition, the influence of anterior internal fixation material or combined anterior and posterior approach on radiation dose at the anterior border of the vertebral body was the greatest. Regardless of the kinds of internal fixation method employed, radiation dose at the anterior border of the vertebral body was significantly different from that at other positions. Notably, the influence of posterior internal fixation material on the anterior wall of the vertebral canal was the greatest. X-ray attenuation and scattering should be taken into consideration for most patients with bone metastasis that receive fixation of metal implants. Further evaluation should then be conducted with modified TPS in order to minimize the potentially harmful effects of inappropriate radiation dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

On the accuracy of dose prediction near metal fixation devices for spine SBRT

The metallic fixations used in surgical procedures to support the spine mechani-cally usually consist of high-density materials. Radiation therapy to palliate spinal cord compression can include prophylactic inclusion of potential tumor around the site of such fixation devices. Determination of the correct density and shape of the spine fixation device has a direct effect on the dose calculatio...

متن کامل

Investigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

متن کامل

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015