Intraoperative validation of mitral inflow determination by transesophageal echocardiography: comparison of single-plane, biplane and thermodilution techniques.
نویسندگان
چکیده
OBJECTIVES This study investigated the accuracy of mitral inflow quantification using biplane transesophageal echocardiography. BACKGROUND Mitral stroke volume can be reliably quantified by transthoracic Doppler echocardiography, but previous studies involving monoplane transesophageal echocardiography have yielded mixed results. METHODS Thirty patients without mitral regurgitation were prospectively examined immediately before cardiovascular surgery. Mitral annulus diameter was measured in the transverse (d1) and longitudinal views (d2) by biplane transesophageal echocardiography. Assuming an elliptic shape, the annular area was calculated as pi d1d2/4; area was also calculated from single-plane data assuming a circular annular shape as pi d2/4. The time-velocity integral of mitral annular Doppler velocity was then multiplied by annular area to yield stroke volume. These data were compared with simultaneous thermodilution measurements by linear regression. RESULTS Good correlations were observed between thermodilution (x) and Doppler (y) measurements of stroke volume (SV) (r = 0.86, p < 0.01, delta SV [y-x] = 2.64 +/- 9.86 ml for single four-chamber view; r = 0.77, p < 0.01, delta SV = 1.82 +/- 12.59 ml for two-chamber view; r = 0.94, p < 0.001, delta SV = 1.78 +/- 5.90 ml for biplane measurements) with similar data for cardiac output (r = 0.82, r = 0.74 and r = 0.92, respectively). The biplane measurements were most accurate and had less variability in individual patients (p < 0.05). This finding was supported by a numerical model that demonstrated (for an ellipse of eccentricity 1.5:1) that even maximal misalignment of biplane diameters yielded only 8% area overestimation, whereas single-plane calculations assuming a circular shape produced a variation in area of 225%. CONCLUSIONS This study validates the accuracy of measurements of mitral inflow using biplane transesophageal echocardiography with potential application for quantification of valvular regurgitation in the operating room. The results are further generalizable, indicating that orthogonal biplane measurements are both necessary and sufficient to ensure accuracy in area calculation for any elliptic structure.
منابع مشابه
Intraoperative transesophageal two-dimensional echocardiography: a basic vertical plane patient examination sequence.
We have previously reported a standardized stepwise transesophageal echocardiography transverse plane (monoplane) patient examination sequence suitable for intraoperative use. Biplane transesophageal echocardiography furnishes images of the heart and great vessels in both transverse and vertical planes. This report describes a seven-step vertical plane examination, the completion component of a...
متن کاملEstimation of mean left atrial pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow.
To determine whether pulmonary venous flow and mitral inflow measured by transesophageal pulsed Doppler echocardiography can be used to estimate mean left atrial pressure (LAP), we prospectively studied 47 consecutive patients undergoing cardiovascular surgery. We correlated Doppler variables of pulmonary venous flow and mitral inflow with simultaneously obtained mean LAP and changes in pressur...
متن کاملPulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.
Two methods of measuring stroke volume and cardiac output with pulsed Doppler two-dimensional echocardiography were developed and validated against the thermodilution technique in 39 patients, 33 of which were in an intensive care unit. With the use of the apical four-chamber view, a mitral inflow method combined the velocity of left ventricular inflow at the mitral anulus with the cross-sectio...
متن کامل[Determination of residual mass in left ventricle by intraoperative transesophageal echocardiography after a giant and floating left atrial myxoma resection].
Atrial myxoma is a benign tumor of the heart that occurs primarily in the left atrium. Floating or large left atrial myxomas frequently cause functional mitral stenosis, may also affect mitral valve structure and flow, and lead to mitral regurgitation. Systemic embolization occurs in around 30% of cases either from tumor fragmentation or complete tumor detachment hence it should be removed as s...
متن کاملEvaluation of biplane color Doppler transesophageal echocardiography in 200 consecutive patients.
BACKGROUND We developed the first biplane transesophageal echocardiography (TEE) probe with two orthogonal transducers, allowing synchronous side-by-side displays of the heart on a monitor TV, and compared its diagnostic value with that of conventional single-plane TEE using commercially available Doppler equipment in 200 consecutive patients intraoperatively, perioperatively, or on an outpatie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 26 4 شماره
صفحات -
تاریخ انتشار 1995