Diagnostic accuracy of central venous saturation in estimating mixed venous saturation is proportional to cardiac performance among cardiac surgical patients.
نویسندگان
چکیده
PURPOSE Advanced hemodynamic monitoring in cardiac surgery translates into improvement in outcomes. We evaluated the relationship between central venous (ScvO2) and mixed venous (SvO2) saturations over the early postoperative period. The adequacy of their interchangeability was tested in patients with varying degrees of cardiac performance. METHODS In this prospective observational study, we evaluated 156 consecutive cardiac surgical patients in an academic center. The ScvO2 and SvO2 data were harvested from 468 paired samples taken preoperatively (T0), after weaning from cardiopulmonary bypass (T1) and on postoperative day 1 (T2). RESULTS The relationship between ScvO2 and SvO2 was inconsistent, with inferior correlations in patients with lower cardiac indices (CI) (Pearson r(2) = 0.37 if CI ≤2.0 L/min per square meter vs r(2) = 0.73 if CI >2.0 L/min per square meter, both P < .01). Patients with lower CI also had wider 95% limits of agreement between SvO2 and ScvO2. The proportion of patients with a negative SvO2-ScvO2 gradient increased over time (48/156 [31%] at T0 to 73/156 [47%] at T2; P < .01). This subgroup more frequently required inotropes at T2 than patients with a positive SvO2-ScvO2 gradient (odds ratio, 6.46 [95% confidence interval, 0.81-51.87], P = .06) and also had higher serum lactate levels (1.5 ± 0.8 vs 1.0 ± 0.4; P < .01). CONCLUSIONS The diagnostic accuracy of ScvO2 for estimating SvO2 is proportional to cardiac performance. A negative SvO2-ScvO2 gradient at T2 correlated with inotropic support requirement, higher operative risk score, age, lactate level, and duration of cardiopulmonary bypass.
منابع مشابه
Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation.
The influence of cardiac output on the correlation between central venous oxygen saturation and mixed venous oxygen saturation was assessed in 51 patients who had both a pulmonary artery catheter and separate central venous catheter in situ. Seventy-six paired samples were taken from the catheters and oxygen saturation measured immediately in a Ciba Corning 2500 Co-oximeter. Cardiac output was ...
متن کاملCentral venous oxygen saturation and blood lactate levels during cardiopulmonary bypass are associated with outcome after pediatric cardiac surgery
INTRODUCTION Central venous oxygen saturation and blood lactate are different indices of the adequacy of oxygen delivery to the oxygen needs. In pediatric cardiac surgery, lactate level and kinetics during and after cardiopulmonary bypass are associated with outcome variables. The aim of this study was to explore the hypothesis that the lowest central venous oxygen saturation and the peak lacta...
متن کاملCorrelation of mixed venous and central venous oxygen saturation and its relation to cardiac index
Background and Aim: The clinical applicability of substitution of central venous oxygen saturation for mixed venous oxygen saturations in monitoring global tissue hypoxia is still a matter of controversy. Hence aim of the study is comparison of paired samples of mixed venous and central venous oxygen saturation and comparison in relation to cardiac index in varying hemodynamic conditio s. Mater...
متن کاملEffects of amrinone on cardiac index, venous oxygen saturation and venous admixture in patients recovering from cardiac surgery.
The hemodynamic and oxygen transport effects of low-dose (0.75 mg/kg loading dose + 10 micrograms/kg/min infusion, n = 12) and high-dose (2.25 mg/kg loading dose + 20 micrograms/kg/min infusion, n = 12) amrinone were evaluated in extubated patients 24 h after CABG. At both doses, amrinone significantly (p less than 0.05) increased HR, but decreased mean arterial, mean pulmonary artery, central ...
متن کاملThe value of venous oximetry.
PURPOSE OF REVIEW Maintenance of adequate tissue oxygenation is an important task in intensive care units. In this context, venous oximetry by obtaining mixed venous oxygen saturation or central venous oxygen saturation has been discussed as useful monitoring parameters. This review discusses the physiology and clinical application of these parameters. RECENT FINDINGS No study has so far demo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of critical care
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2014