Phantom Tracking Method, Homogeneity and Rapid Stabilization
نویسندگان
چکیده
In this paper we explain on various examples the “phantom tracking” method, a method which can be used to stabilize nonlinear control systems modeled by ordinary differential equations or partial differential equations. We show how it can handle global controllability, homogeneity issues or fast stabilization.
منابع مشابه
Design and Fabrication Process of CT number Linearity and Homogeneity Phantom CT Scan
Introduction: One of the most valuable goals of phantoms, replacing with human goals in the field of research and quality control of diagnostic X-ray systems. There are various algorithms and methods for obtaining Homogeneity and CT number linearity for CT scan device. One of the most famous of these methods, the method is to use a uniform and homogeneous environment to comput...
متن کامل4D optimization of scanned ion beam tracking therapy for moving tumors.
Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existi...
متن کاملCardiac Image Registration: Rotational Error Correction and Gated Stabilization for Cardiac Motion.
Background: Dynamic motion of the heart due to cardiac and respiratory cycles, and rotation from varying patient positions between imaging modalities, can cause errors during cardiac image registration. This study used phantom, patient and animal models to assess and correct these errors. Methods and Results: Rotational errors were identified and corrected using different phantom orientations. ...
متن کاملImage Stabilization with Model-Based Tracking for Beating Heart Surgery
Performing surgery on the beating heart has significant advantages compared to cardiopulmonary bypass. However, when performed directly, it is very demanding for the surgeon. As an alternative, using a teleoperated robot for compensating the heart motion has been proposed. As an addition, this paper describes how stabilized images are obtained to create the illusion of operating on a stationary...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کامل